Your browser doesn't support javascript.
loading
Effect of chemical cleaning agents on the flexural strength of acrylic and hard denture line resins.
Rodrigues, Sabrina Alessandra; Nunez Pantoja, Juliana Maria Costa; Takahashi, Jessica Mie Ferreira Koyama; Consani, Rafael Leonardo Xediek; Mesquita, Marcelo Ferraz.
Afiliação
  • Rodrigues SA; Department of Prosthesis and Periodontology, Dental College of Piracicaba, Sao Paulo, Brazil.
Gen Dent ; 61(4): e1-4, 2013 Jul.
Article em En | MEDLINE | ID: mdl-23823352
This study sought to evaluate the disinfectants, Efferdent (EF) and 0.5% sodium hypochlorite (SH), and their effects on the flexural strength and modulus of elasticity of the hard denture liners, Kooliner (K) and New Truliner (NT), and a thermoacrylic resin, QC-20. Ninety specimens were made (50 mm x 10 mm x 3 mm) and divided into 9 groups (n = 10). The 3 control groups were Group 1: QC-20 without disinfection cycles, Group 2: K, and Group 3: NT. The 6 experimental groups were Group 4: QC-20 in EF, Group 5: K in EF, Group 6: NT in EF, Group 7: QC-20 in SH, Group 8: K in SH, and Group 9: NT in SH. Specimens were subjected to 360 cycles of disinfection involving 35-minute cycles of immersion in cleaning solutions. The materials' flexural strength and modulus of elasticity were determined using a universal testing machine at a 5 mm/minute speed of compression. The data were subjected to ANOVA, Tukey, Kruskal-Wallis, and Dunn tests (α = 0.05). Regardless of the disinfection method used, the NT hard denture liner showed the lowest flexural strength values (P < 0.05) and modulus of elasticity (P < 0.0001) compared to K and QC-20. However, flexural strength values increased after applying SH and EF (P < 0.05). QC-20 showed a higher modulus of elasticity (P < 0.033), which increased after EF was applied (P = 0.005). It can be concluded that the disinfection methods changed the mechanical properties of the tested materials.
Assuntos
Palavras-chave
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Maleabilidade / Reembasadores de Dentadura Idioma: En Revista: Gen Dent Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Maleabilidade / Reembasadores de Dentadura Idioma: En Revista: Gen Dent Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos