Your browser doesn't support javascript.
loading
Macular hole: 10 and 20-MHz ultrasound and spectral-domain optical coherence tomography.
Bottós, Juliana Mantovani; Torres, Virginia Laura Lucas; Kanecadan, Liliane Andrade Almeida; Martinez, Andrea Alejandra Gonzalez; Moraes, Nilva Simeren Bueno; Maia, Mauricio; Allemann, Norma.
Afiliação
  • Bottós JM; Department of Ophthalmology, Universidade Federal de São Paulo - UNIFESP, São Paulo, SP, Brazil.
Arq Bras Oftalmol ; 75(6): 415-9, 2012.
Article em En | MEDLINE | ID: mdl-23715145
PURPOSE: Optical coherence tomography (OCT) is valuable for macula evaluation. However, as this technique relies on light energy it cannot be performed in the presence of opaque media. In such cases, the ultrasound (US) may predict some macular features. The aim of this study was to characterize images obtained by ultrasound with 10 and 20-MHz transducers comparing to OCT, as well as to analyze the relationship between the vitreous and retina in eyes with macular hole (MH). METHODS: 29 eyes of 22 patients with biomicroscopic evidence of MH at different stages were included. All patients were evaluated using ultrasonography with 10 and 20-MHz transducers and OCT. RESULTS: OCT identified signs of MH in 25 of 29 eyes. The remaining 4 cases not identified by US were pseudoholes caused by epiretinal membranes. In MH stages I (2 eyes) and II (1 eye), both transducers were not useful to analyze the macular thickening, but suggestive findings as macular irregularity, operculum or partial posterior vitreous detachment (PVD) were highlighted. In stages III (14 eyes) and IV (5 eyes), both transducers identified the double hump irregularity and thickening. US could measure the macular thickness and other suggestive findings for MH: operculum, vitreomacular traction and partial or complete PVD. In cases of pseudoholes, US identified irregularities macular contour and a discrete depression. CONCLUSION: 10-MHz US was useful for an overall assessment of the vitreous body as well as its relationship to the retina. The 20-MHz transducer allowed valuable information on the vitreomacular interface and macular contour. OCT provides superior quality for fine morphological study of macular area, except in cases of opaque media. In these cases, and even if OCT is not available, the combined US study is able to provide a valid evaluation of the macular area improving therapeutic approach.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Retina / Perfurações Retinianas / Corpo Vítreo / Descolamento do Vítreo / Tomografia de Coerência Óptica Tipo de estudo: Prognostic_studies Limite: Aged / Child / Female / Humans / Male / Middle aged Idioma: En Revista: Arq Bras Oftalmol Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Retina / Perfurações Retinianas / Corpo Vítreo / Descolamento do Vítreo / Tomografia de Coerência Óptica Tipo de estudo: Prognostic_studies Limite: Aged / Child / Female / Humans / Male / Middle aged Idioma: En Revista: Arq Bras Oftalmol Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil