Your browser doesn't support javascript.
loading
Determination of the network structure of sensor materials prepared by three different sol-gel routes using Fourier transform infrared spectroscopy (FT-IR).
Cappeletti, Larissa B; Moncada, Edwin; Poisson, Joel; Butler, Ian S; Dos Santos, João Henrique Z.
Afiliação
  • Cappeletti LB; Instituto de Química, UFRGS, Av. Bento Gonçalves, 9500, Porto Alegre, Brazil.
Appl Spectrosc ; 67(4): 441-7, 2013 Apr.
Article em En | MEDLINE | ID: mdl-23601544
Solid acid-base sensor materials were prepared by encapsulating three pH indicators (alizarin red, brilliant yellow, and acridine) within a silica matrix using a sol-gel approach through three different routes: (1) non-hydrolytic, (2) acid-catalyzed, and (3) base-catalyzed. Raman and Fourier transform infrared spectroscopies were used to evaluate the silica-indicator interactions. Because vibrational bands assigned to functional groups present in the indicator molecules were not detected, the main silica stretching mode νSi-O between approximately 1300 and 1000 cm(-1) was used to detect the presence of our indicators within the silica matrix. The large band centered at 1100 cm(-1) was deconvoluted into four components corresponding to the longitudinal optic and transversal optic modes of the silicon monoxide (SiO)4 and (SiO)6 siloxane rings. Using the component area of each mode, it was possible to calculate the percentage of each structure. Such percentages ranged from 49% to 70% (SiO)6 for the analyzed samples, within a confidence level of 95% (p = 0.05). (The confidence limits were 53-62%.) These results could be related to the pH indicator content, indicating that the quantity of the encapsulated molecule affects the (SiO)6 percentage values. In addition, a comparison with the radius of gyration obtained by small angle X-ray scattering was done. These results indicate that the analyte accesses the receptor elements through the passages between the siloxane rings but not through the siloxane rings themselves.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectroscopia de Infravermelho com Transformada de Fourier / Transição de Fase Idioma: En Revista: Appl Spectrosc Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectroscopia de Infravermelho com Transformada de Fourier / Transição de Fase Idioma: En Revista: Appl Spectrosc Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos