Your browser doesn't support javascript.
loading
Transcatheter aortic valve implantation without balloon predilation: a single-center pilot experience.
Mendiz, Oscar A; Fraguas, Hugo; Lev, Gustavo A; Valdivieso, Leon R; Favaloro, Roberto R.
Afiliação
  • Mendiz OA; Department of Interventional Cardiology and Cardiovascular Surgery, Hospital Universitario, Fundación Favaloro, Buenos Aires, Argentina. omendiz@ffavaloro.org
Catheter Cardiovasc Interv ; 82(2): 292-7, 2013 Aug 01.
Article em En | MEDLINE | ID: mdl-23554013
AIM: To assess the results of transcatheter aortic valve implantation (TAVI) using the Medtronic CoreValve prosthesis (Medtronic, Minneapolis, MN), without balloon predilation, in high-risk patients with degenerated severe aortic stenosis. METHODS AND RESULTS: Fifty-one consecutive patients who underwent direct TAVI, 98% through a transfemoral approach. Patients were 79 ± 8 years of age, 74% in New York Heart Association classes III or IV and at high risk for surgical valve replacement (mean logistic EuroScore 20 ± 15). Mean aortic valve area was 0.7 ± 0.2 cm(2). Procedural success rate was 94.2%. In-hospital, there were 2 deaths, 1 minor stroke with minimal sequelae, and 14 (28%) pacemaker implantation. At 30 days, there was one additional stroke and no new deaths. The mean postprocedural transprosthetic gradient was 15 ± 5 mm Hg; periprosthetic severe regurgitation was absent and moderate in one case. After a median follow-up of 7 months, there were five additional deaths (two cardiac), while 84% of survivors were in New York Heart Association classes I or II. CONCLUSIONS: These results suggest that direct CoreValve implantation in patients with severe aortic stenosis is feasible and may lead to hemodynamic and clinical improvement in patients who are poor candidates for aortic valve surgery, pending confirmation in larger series with longer follow-up.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Calcinose / Cateterismo Cardíaco / Implante de Prótese de Valva Cardíaca Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Limite: Aged80 País/Região como assunto: America do sul / Argentina Idioma: En Revista: Catheter Cardiovasc Interv Assunto da revista: CARDIOLOGIA Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Argentina País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Calcinose / Cateterismo Cardíaco / Implante de Prótese de Valva Cardíaca Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Limite: Aged80 País/Região como assunto: America do sul / Argentina Idioma: En Revista: Catheter Cardiovasc Interv Assunto da revista: CARDIOLOGIA Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Argentina País de publicação: Estados Unidos