Ex vivo accuracy of three electronic apex locators using different apical file sizes.
Vasconcelos, Bruno Carvalho de; Matos, Leonardo de Alencar; Pinheiro-Júnior, Elilton Cavalcante; Menezes, Antônio Sérgio Teixeira de; Vivacqua-Gomes, Nilton.
Afiliação
  • Vasconcelos BC; Sobral Dental School, Federal University of Ceará, Sobral, CE, Brazil. bcv@ufc.br
Braz Dent J ; 23(3): 199-204, 2012.
Article em En | MEDLINE | ID: mdl-22814686
This study evaluated the accuracy of three electronic apex locators (Root ZX, Novapex, and Justy II) in root canal length determinations using different apical file sizes, considering the apical constriction (AC) and the major foramen (MF) as anatomic references. The diameter of the apical foramina of 40 single-rooted teeth was determined by direct visual measurement and the master apical file was established. Electronic measurements were then performed using 3 instruments: the selected master apical file (adjusted file), one size smaller (intermediate file), and two sizes smaller (misfit file). The distances from the tip of files fixed in the canals to the MF and to the AC were measured digitally. Precision at AC and at MF for the misfit, intermediate and adjusted apical files was as follows: 80%/88%/83% and 78%/83%/95% (Root ZX); 80%/85%/80% and 68%/73%/73% (Novapex); and 78%/80%/78% and 65%/78%/70% (Justy II). Considering the mean discrepancies, statistically significant differences were found only for the adjusted file at MF, with Root ZX presenting the best results at MF. The chi-square test showed significant differences between the acceptable measurements at AC and at MF for the Justy II and Novapex (± 0.5 mm) regardless of file adjustment. Under the conditions of the present study, all devices provided acceptable electronic measurements regardless of file adjustment, except for Root ZX which had its performance improved significantly when the precisely fit apical file was used. Justy II and Novapex provided electronic measurements nearest to the AC.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Raiz Dentária / Preparo de Canal Radicular / Ápice Dentário / Odontometria Limite: Humans Idioma: En Revista: Braz Dent J Assunto da revista: ODONTOLOGIA Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Raiz Dentária / Preparo de Canal Radicular / Ápice Dentário / Odontometria Limite: Humans Idioma: En Revista: Braz Dent J Assunto da revista: ODONTOLOGIA Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil