Your browser doesn't support javascript.
loading
Method validation for the determination of total mercury in fish muscle by cold vapour atomic absorption spectrometry.
Nascimento Neto, A P; Costa, L C S Magalhães; Kikuchi, A N S; Furtado, D M S; Araujo, M Q; Melo, M C C.
Afiliação
  • Nascimento Neto AP; Laboratory of Residues and Contaminants, National Laboratory of Ministry of Agriculture, Livestock and Food Supply (LANAGRO-PA), Brazil, Av. Almirante Barroso, 1234, 66095-000, Brazil. antonio.nascimento@agricultura.gov.br
Article em En | MEDLINE | ID: mdl-22250927
A method was validated for the determination of total Hg in fish muscle using continuous flow cold vapour atomic absorption (CVAAS) after microwave digestion in closed vessels. The method was validated according to European Union Regulations 333/2007 and 657/2002, considering the maximum level for the metal in fish, established by European Union regulation 1881/2006. The procedure for determining linear range, selectivity, recovery, precision, trueness, decision limit (CCα), detection capability (CCß), measurement uncertainty and robustness of the method is reported. The results of the validation process demonstrate the method fulfils the provisions of the Commission Regulation. The selectivity study indicated that there was no matrix effect on the calibration curve between the concentration range of 1.0 and 30.0 µg Hg l(-1). The mean recovery calculated at six levels of fortification was in the range of 94-104%. The limit of detection (LOD) and limit of quantification (LOQ) values were 4.90 and 15.7 µg kg(-1), while the CCα and CCß values were 0.517 and 0.533 mg kg(-1), respectively, for the maximum contaminant level of 0.500 mg kg(-1). The relative expanded measurement uncertainty of the method was 0.055 mg kg(-1). The method was not affected by slight variations of some critical factors (ruggedness minor changes) as sample mass and volume of the HNO(3) and H(2)O(2) used in the digestion step. The method allowed accurate confirmation analyses of the CRM DORM 3. In fact, the Z-scores attained in a proficiency test round were well below the reference value of 2.0, proving the excellent performance of the laboratory.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrofotometria Atômica / Contaminação de Alimentos / Alimentos Marinhos / Mercúrio / Músculos Tipo de estudo: Prognostic_studies Limite: Animals País/Região como assunto: America do sul / Brasil Idioma: En Revista: Food Addit Contam Part A Chem Anal Control Expo Risk Assess Assunto da revista: CIENCIAS DA NUTRICAO Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Brasil País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrofotometria Atômica / Contaminação de Alimentos / Alimentos Marinhos / Mercúrio / Músculos Tipo de estudo: Prognostic_studies Limite: Animals País/Região como assunto: America do sul / Brasil Idioma: En Revista: Food Addit Contam Part A Chem Anal Control Expo Risk Assess Assunto da revista: CIENCIAS DA NUTRICAO Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Brasil País de publicação: Reino Unido