Abutment rotational freedom evaluation of external hexagon single-implant restorations after mechanical cycling.
Junqueira, Marcela C; Silva, Thales Eduardo P; Ribeiro, Ricardo F; Faria, Adriana Cláudia L; Macedo, Ana Paula; de Almeida, Rossana P.
Afiliação
  • Junqueira MC; postgraduated student, titular professor, research laboratory specialist, associated professor, Department of Dental Materials and Prosthodontics, Dental School of Ribeirao Preto, University of Sao Paulo, Ribeirao Preto, Sao Paulo, Brazil.
Clin Implant Dent Relat Res ; 15(6): 927-33, 2013 Dec.
Article em En | MEDLINE | ID: mdl-22236420
PURPOSE: The purpose of this study was to evaluate the rotational freedom between implant and abutment counterpart of two abutments types over external hexagon implants submitted to mechanical cycling. MATERIALS AND METHODS: Ten implants with external hexagon (3.75 mm × 13 mm), five cast abutments, and five premachined abutments both with 4.1 mm plataform size were used in this study. Ten metallic crowns were fabricated using the two types of abutments and were fixed to each implant using titanium screws (Ti6Al4V). Rotational freedom measurements were made before and after the cast procedure and after the mechanical cycling. Groups were classified according to the rotational misfit register using University of California, Los Angeles abutment and implants as new (group 1 = G1); using crowns and implants after crown casting (group 2 = G2); and using crowns and implants after mechanical cycling (group 3 = G3). Oblique loading of 120N at 1.8 Hz and 5 × 10(5) cycles was applied on specimen. RESULTS: Statistical analysis (p < .05) showed that no significant difference was observed when cast abutment was compared with premachined abutment after casting (p = .390) and mechanical cycling (p = .439); however, significant difference was noted before the casting (p = .005) with higher values for the cast abutments. CONCLUSIONS: Within the limitations of this in vitro study, it could be concluded that the abutment type used do not influenced the rotational freedom after casting and the amount of applied cycles (500,000 cycles) was not sufficient to significantly alter the values of rotational freedom at the implant/abutment joint.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dente Suporte / Implantes Dentários para Um Único Dente Limite: Humans Idioma: En Revista: Clin Implant Dent Relat Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dente Suporte / Implantes Dentários para Um Único Dente Limite: Humans Idioma: En Revista: Clin Implant Dent Relat Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos