Your browser doesn't support javascript.
loading
[Diagnostic accuracy of the fine needle aspiration cytology and core needle biopsy as a diagnostic method for breast lesions]. / Acurácia da punção aspirativa por agulha fina e da punção por agulha grossa no diagnóstico de lesões mamárias.
Frankel, Patrícia Pontes; Esteves, Viviane Fernandes; Thuler, Luiz Claudio Santos; Vieira, Roberto José da Silva.
Afiliação
  • Frankel PP; Instituto Fernandes Figueira, Fundação Oswaldo Cruz, Rio de Janeiro, RJ, Brasil.
Rev Bras Ginecol Obstet ; 33(3): 139-43, 2011 Mar.
Article em Pt | MEDLINE | ID: mdl-21829998
PURPOSE: to determine the accuracy of fine-needle aspiration biopsy (FNAB) and of core-needle biopsy (CNB) in diagnosing breast lumps and breast cancer. METHODS: this was a cross-sectional, retrospective and descriptive study based on the review of medical records. FNAB and CNB were carried out sequentially according to the routine of the Mastology Service. Both percutaneous procedures were applied to 233 patients during the period from March 2005 to February 2007. Women aged 18 years or more with changes in the clinical and/or image examination of the breast or a family history of breast and/or ovarian cancer were included. FNAB and CNB were carried out according to the technical recommendations of the National Institute of Cancer. The percentage of agreement, Cohen's Kappa coefficient, sensitivity, specificity, positive and negative predictive values and the accuracy of FNAB and CNB were calculated, considering the surgical biopsy as the gold standard. RESULTS: the average age of the patients was 49.0 years (±12.7) and the tumors measured 26.9 mm on average (±23.1), being larger than 20 mm in 47.2% of cases. Sensitivity, specificity, positive and negative predictive values and accuracy were higher for CNB than for FNAB, regardless of the size of the breast lesion. The diagnostic accuracy was 97.5% for CNB and 77.5% for FNAB. CONCLUSION: although the CNB showed higher rates of sensitivity, specificity, positive predictive value, negative predictive value and accuracy than FNAB for palpable and non-palpable breast lumps, the method remains useful for the minimally invasive diagnosis of mammary lesions, especially when its results are analyzed together with the clinical and imaging examination.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Biópsia por Agulha / Neoplasias da Mama Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Middle aged Idioma: Pt Revista: Rev Bras Ginecol Obstet Assunto da revista: GINECOLOGIA / OBSTETRICIA Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Biópsia por Agulha / Neoplasias da Mama Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Middle aged Idioma: Pt Revista: Rev Bras Ginecol Obstet Assunto da revista: GINECOLOGIA / OBSTETRICIA Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil