Your browser doesn't support javascript.
loading
Heart failure: comparison between six-minute walk test and cardiopulmonary test.
Carvalho, Eduardo Elias Vieira de; Costa, Daniela Caetano; Crescêncio, Júlio César; Santi, Giovani Luiz De; Papa, Valéria; Marques, Fabiana; Schmidt, André; Marin-Neto, José Antonio; Simões, Marcus Vinícius; Gallo Junior, Lourenço.
Afiliação
  • Carvalho EE; Departamento de Clínica Médica Laboratório de Fisiologia do Exercício, Divisão de Cardiologia, Faculdade de Medicina de Ribeirão Preto, USP, Brazil. carvalhoeev@usp.br
Arq Bras Cardiol ; 97(1): 59-64, 2011 Jul.
Article em En, Pt, Es | MEDLINE | ID: mdl-21552646
BACKGROUND: Chronic heart failure (HF) is a syndrome characterized by reduced cardiac output in relation to the metabolic needs of the organism, as well as metabolic and neurohormonal axis abnormalities. Symptoms such as fatigue and dyspnoea are notorious and stress tests are widely used to assess functional capacity, prognosis and effectiveness of therapeutic interventions in this syndrome. OBJECTIVE: To evaluate the reproducibility of the six-minute walk test (6MW) in patients with HF and correlate the magnitude of the variables reached at peak exercise of the 6MWT with a cardiopulmonary exercise test (CPET). METHODS: We studied 16 patients (12 men and 4 women) diagnosed with HF FC I-II (NYHA). The volunteers underwent two 6MWT (6MWT'1 and 6MWT'2) with 30-minute interval between them; then, they underwent a maximum CPET. RESULTS: All variables obtained in the two 6MWT' proved to be significant with high correlations: distance walked (DW) (r = 0.93, p < 0.0001), heart rate (HR) (r = 0.89, p < 0.0001), oxygen consumption (VO2) (r = 0.93, p < 0.0001) and scale of perceived exertion (r = 0.85, p < 0.0001). In turn, all variables analyzed in the 6MWT' showed significant and moderate correlations with the variables obtained from the CPET, namely: peak HR (r = 0.66; p = 0.005); VO2 (r = 0.57; p = 0.02) and VO2 in the CPET and DT in the 6MWT'2 (r = 0.70; p = 0.002). CONCLUSION: The 6MWT was reproducible in this group of patients with HF (NYHA - I-II) and correlated with the CPET. Therefore, it is a tool for reliable evaluation, and a suitable, safe and low-cost alternative for the prescription of aerobic exercise in patients with HF.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Teste de Esforço / Insuficiência Cardíaca Tipo de estudo: Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En / Es / Pt Revista: Arq Bras Cardiol Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Teste de Esforço / Insuficiência Cardíaca Tipo de estudo: Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En / Es / Pt Revista: Arq Bras Cardiol Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil