Your browser doesn't support javascript.
loading
Evaluation of a 3D stereophotogrammetric technique to measure the stone casts of patients with unilateral cleft lip and palate.
Sforza, Chiarella; De Menezes, Marcio; Bresciani, Elena; Cerón-Zapata, Ana M; López-Palacio, Ana M; Rodriguez-Ardila, Myriam J; Berrio-Gutiérrez, Lina M.
Afiliação
  • Sforza C; Dipartimento di Morfologia Umana e Scienze Biomediche Città Studi, via Mangiagalli 31, I-20133 Milano, Italy. chiarella.sforza@unimi.it
Cleft Palate Craniofac J ; 49(4): 477-83, 2012 Jul.
Article em En | MEDLINE | ID: mdl-21417780
OBJECTIVE: To assess a three-dimensional stereophotogrammetric method for palatal cast digitization of children with unilateral cleft lip and palate. DESIGN: As part of a collaboration between the University of Milan (Italy) and the University CES of Medellin (Colombia), 96 palatal cast models obtained from neonatal patients with unilateral cleft lip and palate were obtained and digitized using a three-dimensional stereophotogrammetric imaging system. MAIN OUTCOME MEASURES: Three-dimensional measurements (cleft width, depth, length) were made separately for the longer and shorter cleft segments on the digital dental cast surface between landmarks, previously marked. Seven linear measurements were computed. Systematic and random errors between operators' tracings, and accuracy on geometric objects of known size were calculated. In addition, mean measurements from three-dimensional stereophotographs were compared statistically with those from direct anthropometry. RESULTS: The three-dimensional method presented good accuracy error (<0.9%) on measuring geometric objects. No systematic errors between operators' measurements were found (p > .05). Statistically significant differences (p < 5%) were noted for different methods (caliper versus stereophotogrammetry) for almost all distances analyzed, with mean absolute difference values ranging between 0.22 and 3.41 mm. Therefore, rates for the technical error of measurement and relative error magnitude were scored as moderate for Ag-Am and poor for Ag-Pg and Am-Pm distances. Generally, caliper values were larger than three-dimensional stereophotogrammetric values. CONCLUSIONS: Three-dimensional stereophotogrammetric systems have some advantages over direct anthropometry, and therefore the method could be sufficiently precise and accurate on palatal cast digitization with unilateral cleft lip and palate. This would be useful for clinical analyses in maxillofacial, plastic, and aesthetic surgery.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fotogrametria / Fenda Labial / Fissura Palatina / Imageamento Tridimensional / Modelos Dentários Tipo de estudo: Prognostic_studies Limite: Child / Female / Humans / Male País/Região como assunto: America do sul / Colombia / Europa Idioma: En Revista: Cleft Palate Craniofac J Assunto da revista: ODONTOLOGIA Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Itália País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fotogrametria / Fenda Labial / Fissura Palatina / Imageamento Tridimensional / Modelos Dentários Tipo de estudo: Prognostic_studies Limite: Child / Female / Humans / Male País/Região como assunto: America do sul / Colombia / Europa Idioma: En Revista: Cleft Palate Craniofac J Assunto da revista: ODONTOLOGIA Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Itália País de publicação: Estados Unidos