Martensitic transformation of austenitic stainless steel orthodontic wires during intraoral exposure.
Am J Orthod Dentofacial Orthop
; 138(6): 714.e1-5; discussion 714-5, 2010 Dec.
Article
em En
| MEDLINE
| ID: mdl-21130328
INTRODUCTION: Our purpose was to study the mechanical properties and phase transformations of orthodontic wires submitted to in-vivo exposure in the mouth for different periods of time. METHODS: Stainless steel wires were tied to fixed orthodontic appliances of 30 patients from the orthodontics clinic of Universidade Federal do Rio de Janeiro School of Dentistry in Brazil. According to the duration of the clinical treatment, the patients were divided into 3 groups. After in-vivo exposure, the samples were studied by mechanical testing (torsion) and ferromagnetic resonance. Statistical analyses were carried out to evaluate the correlation between time of exposure, mechanical properties, and austenite-to-martensite transformation among the groups. RESULTS: The results were compared with as-received control samples. The torque values increased as time in the mouth increased. The increase in torque resistance showed high correlations with time of exposure (P = 0.005) and austenite-martensite phase transformation. CONCLUSIONS: The resistance of stainless steel orthodontic wires increases as the time in the mouth increases; this effect is attributed to the austenite-to-martensite transformation.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Fios Ortodônticos
/
Aço Inoxidável
/
Ligas Dentárias
/
Boca
Tipo de estudo:
Clinical_trials
Limite:
Humans
Idioma:
En
Revista:
Am J Orthod Dentofacial Orthop
Assunto da revista:
ODONTOLOGIA
/
ORTODONTIA
Ano de publicação:
2010
Tipo de documento:
Article
País de afiliação:
Brasil
País de publicação:
Estados Unidos