Your browser doesn't support javascript.
loading
Evaluation of the conversion degree, microhardness, and surface roughness of composite resins used after their expiration date.
Garcia, Lucas da Fonseca Roberti; Roselino, Lourenco de Moraes Rego; Pires-de-Souza, Fernanda de Carvalho Panzeri; Consani, Simonides.
Afiliação
  • Garcia Lda F; Piracicaba School of Dentistry, State University of Campinas, Piracicaba, Sao Paolo, Brazil.
Gen Dent ; 58(6): e262-7, 2010.
Article em En | MEDLINE | ID: mdl-21062711
This study evaluated the conversion degree associated with microhardness and surface roughness of four composite resins used 180 days before and after their expiration dates. Ten specimens of each composite were made in a Teflon matrix (2 mm x 7 mm), separated into two groups (n = 10), and submitted to Vickers microhardness (a 10 N load for 15 seconds), R(a)roughness (cut-off 0.25 mm), and conversion degree evaluation. The data submitted to the two-way ANOVA (p < 0.05) showed a reduction in microhardness for the composites used after their expiration dates. It was concluded that the expired composites had altered properties.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Resinas Compostas / Materiais Dentários Limite: Humans Idioma: En Revista: Gen Dent Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos
Buscar no Google