Computer-assisted methods to evaluate retinal vascular caliber: what are they measuring?
Pakter, Helena M; Fuchs, Sandra C; Maestri, Marcelo K; Moreira, Leila B; Dei Ricardi, Luciana M; Pamplona, Vítor F; Oliveira, Manuel M; Fuchs, Flávio D.
Afiliação
  • Pakter HM; Postgraduate Studies Program in Epidemiology, UFRGS (Universidade Federal do Rio Grande do Sul), Porto Alegre, RS (Rio Grande do Sul), Brazil.
Invest Ophthalmol Vis Sci ; 52(2): 810-5, 2011 Feb 09.
Article em En | MEDLINE | ID: mdl-21051725
PURPOSE: Computer-assisted methods to measure retinal vessel diameters have been incorporated into research, but it is not clear which component of the vessels they are measuring. This study was conducted to compare measurements of retinal vessel diameter by using imaging-processing software on color fundus photographs (FPs) and fluorescein angiographs (FAs). METHODS: FP and FA images were taken simultaneously in 52 eyes of 31 patients referred for angiography for diagnosis of retinal disease. Arteriolar and venular calibers were measured in two concentric zones around the optic disc center. Pearson correlation coefficients and Bland-Altman plots were used to evaluate the agreement between the measurements made by FP and FA. RESULTS: The differences between the diameters measured by the microdensitometric method from FP and FA were 2.59 ± 8.67 µm in the inner arteriola, 4.93 ± 7.47 µm in the outer arteriola, -1,58 ± 8.49 µm in the inner venula, and -1.80 ± 7.28 µm in the outer venula. The differences plotted by the Bland-Altman method were slight. The Pearson correlation coefficients of measurements by FP and FA were 0.84 for inner zone and 0.87 for outer zone arterioles and 0.93 and 0.94 for the inner and outer zone venules, respectively. CONCLUSIONS: The very slight differences between measurements of retinal vessel diameter by the two methods demonstrate that the microdensitometric method mostly measures the vessel lumen. Differences in vessel diameters measured by the microdensitometric method observed in clinical conditions may therefore be ascribed to variation in wall thickness or vasoconstriction.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vasos Retinianos / Processamento de Imagem Assistida por Computador / Angiofluoresceinografia / Fotografação Tipo de estudo: Diagnostic_studies / Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Invest Ophthalmol Vis Sci Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vasos Retinianos / Processamento de Imagem Assistida por Computador / Angiofluoresceinografia / Fotografação Tipo de estudo: Diagnostic_studies / Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Invest Ophthalmol Vis Sci Ano de publicação: 2011 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos