Intrasession, intersession, and interexaminer variabilities of retinal nerve fiber layer measurements with spectral-domain OCT.
Eur J Ophthalmol
; 21(3): 264-70, 2011.
Article
em En
| MEDLINE
| ID: mdl-20853266
PURPOSE: To evaluate the intrasession, intersession, and interexaminer variabilities of retinal nerve fiber layer measurements (RNFL) with spectral-domain optical coherence tomography (OCT). METHODS: A total of 32 healthy individuals and 34 patients with chronic glaucoma underwent RNFL measurements with the Cirrus HD-OCT Model 4000 (Carl Zeiss Meditec, Dublin, CA, USA) 5 times during the same sitting by one examiner to assess intrasession variability. The same examiner performed RNFL measurements in the same patients on 5 different days to assess intersession variability. A second examiner performed RNFL measurements in the same patients to assess interexaminer variability. The coefficients of variation and intraclass correlation coefficients were obtained for the following parameters: average thickness, quadrant thickness, and Clock hour thickness measurements. RESULTS: Intrasession variability: In patients with glaucoma, coefficients of variation ranged from 4.51% to 11.84%. Intraclass correlation coefficients ranged from 0.74 to 0.99. In healthy individuals, coefficients of variation ranged from 2.92% to 6.99%. Intraclass correlation coefficients ranged from 0.89 to 0.98. Intersession variability: In patients with glaucoma, coefficients of variation ranged from 3.68% to 10.50%. Intraclass correlation coefficients ranged from 0.82 to 0.99. In healthy individuals, coefficients of variation ranged from 3.13% to 6.92%. Intraclass correlation coefficients ranged from 0.87 to 0.99. Interexaminer variability: In patients with glaucoma, coefficients of variation ranged from 2.62% to 14.94%. Intraclass correlation coefficients ranged from 0.55 to 0.98. In healthy individuals, coefficients of variation ranged from 2.04% to 7.31%. Intraclass correlation coefficients ranged from 0.86 to 0.98. CONCLUSIONS: These findings indicate that RNFL measurements with spectral-domain OCT display excellent reproducibility, with low intrasession, intersession, and interexaminer variabilities.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Disco Óptico
/
Células Ganglionares da Retina
/
Doenças do Nervo Óptico
/
Glaucoma
/
Tomografia de Coerência Óptica
/
Fibras Nervosas
Tipo de estudo:
Prognostic_studies
Limite:
Adult
/
Aged
/
Aged80
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Eur J Ophthalmol
Assunto da revista:
OFTALMOLOGIA
Ano de publicação:
2011
Tipo de documento:
Article
País de afiliação:
Brasil
País de publicação:
Estados Unidos