Your browser doesn't support javascript.
loading
Influence of artificial accelerated aging on dimensional stability of acrylic resins submitted to different storage protocols.
Garcia, Lucas da Fonseca Roberti; Roselino, Lourenço de Moraes Rego; Mundim, Fabrício Mariano; Pires-de-Souza, Fernanda de Carvalho Panzeri; Consani, Simonides.
Afiliação
  • Garcia Lda F; Department of Restorative Dentistry, Dental Materials Area, Piracicaba Dental School, Campinas State University, Piracicaba, Brazil.
J Prosthodont ; 19(6): 432-7, 2010 Aug.
Article em En | MEDLINE | ID: mdl-20546494
PURPOSE: The aim of this study was to evaluate the influence of artificial accelerated aging on dimensional stability of two types of acrylic resins (thermally and chemically activated) submitted to different protocols of storage. MATERIALS AND METHODS: One hundred specimens were made using a Teflon matrix (1.5 cm x 0.5 mm) with four imprint marks, following the lost-wax casting method. The specimens were divided into ten groups, according to the type of acrylic resin, aging procedure, and storage protocol (30 days). GI: acrylic resins thermally activated, aging, storage in artificial saliva for 16 hours, distilled water for 8 hours; GII: thermal, aging, artificial saliva for 16 hours, dry for 8 hours; GIII: thermal, no aging, artificial saliva for 16 hours, distilled water for 8 hours, GIV: thermal, no aging, artificial saliva for 16 hours, dry for 8 hours; GV: acrylic resins chemically activated, aging, artificial saliva for 16 hours, distilled water for 8 hours; GVI: chemical, aging, artificial saliva for 16 hours, dry for 8 hours; GVII: chemical, no aging, artificial saliva for 16 hours, distilled water for 8 hours; GVIII: chemical, no aging, artificial saliva for 16 hours, dry for 8 hours GIX: thermal, dry for 24 hours; and GX: chemical, dry for 24 hours. All specimens were photographed before and after treatment, and the images were evaluated by software (UTHSCSA - Image Tool) that made distance measurements between the marks in the specimens (mm), calculating the dimensional stability. Data were submitted to statistical analysis (two-way ANOVA, Tukey test, p= 0.05). RESULTS: Statistical analysis showed that the specimens submitted to storage in water presented the largest distance between both axes (major and minor), statistically different (p < 0.05) from control groups. CONCLUSIONS: All acrylic resins presented dimensional changes, and the artificial accelerated aging and storage period influenced these alterations.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Resinas Acrílicas / Materiais Dentários Tipo de estudo: Guideline Limite: Humans Idioma: En Revista: J Prosthodont Assunto da revista: ODONTOLOGIA Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Resinas Acrílicas / Materiais Dentários Tipo de estudo: Guideline Limite: Humans Idioma: En Revista: J Prosthodont Assunto da revista: ODONTOLOGIA Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos