Your browser doesn't support javascript.
loading
[Wavefront-guided Lasik for low to moderate myopia: CustomCornea versus Zyoptix]. / Estudo comparativo entre duas plataformas para realização de Lasik personalizado para correção de miopia e astigmatismo: Alcon CustomCornea versus Bausch & Lomb Zyoptix.
Barreiro, Telma Pereira; Forseto, Adriana dos Santos; Pinto, Lucila Ferreira Leite; Francesconi, Claudia Maria; Nosé, Walton.
Afiliação
  • Barreiro TP; Eye Clinic Day Hospital, São Paulo, SP, Brazil. telma.pereira@uol.com.br
Arq Bras Oftalmol ; 72(4): 519-25, 2009.
Article em Pt | MEDLINE | ID: mdl-19820793
PURPOSE: To compare the visual and clinical outcomes of Wavefront-guided laser in situ keratomileusis (Lasik) with Alcon CustomCornea and Zyoptix systems. METHODS: A prospective, randomized, masked and bilateral study was conducted. Fifty patients with preoperative spherical equivalent ranging from -1.00 to -6.50 D were enrolled for customized ablation in both eyes. All of them were submitted to Lasik CustomCornea treatment in one eye and Zyoptix in the other eye. Uncorrected visual acuity, best correct visual acuity (BCVA), manifest refraction, wavefront measurements, and contrast sensitivity testing were performed preoperatively and postoperatively at 1, 3 and 6 months. RESULTS: Preoperatively manifest refractive spherical equivalent was -3.29+/-1.56 D in the CustomCornea group and -3.22+/-1.50 D in the Zyoptix group. At 6 months, 86% of CustomCornea eyes and 70% of Zyoptix eyes had UCVA>or=20/20. One hundred percent of the CustomCornea group and 88% of the eyes in the Zyoptix were within 0.50 D of emmetropia. In both groups, the contrast sensitivity improved. Spherical aberration increased in both groups, with the CustomCornea group showing lower levels (p<0.001). CONCLUSION: There were no differences between the systems according to safety and effectiveness. The Zyoptix platform showed greater spherical aberration.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Acuidade Visual / Ceratomileuse Assistida por Excimer Laser In Situ / Miopia Tipo de estudo: Clinical_trials / Observational_studies Limite: Adult / Humans Idioma: Pt Revista: Arq Bras Oftalmol Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Acuidade Visual / Ceratomileuse Assistida por Excimer Laser In Situ / Miopia Tipo de estudo: Clinical_trials / Observational_studies Limite: Adult / Humans Idioma: Pt Revista: Arq Bras Oftalmol Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil