Your browser doesn't support javascript.
loading
[Use of bioelectrical impedance for the estimation of skeletal muscle mass in elderly men]. / Utilização da impedância bioelétrica para estimativa da massa muscular esquelética em homens idosos.
Augustemak de Lima, Luiz Rodrigo; Rech, Cassiano Ricardo; Petroski, Edio Luiz.
Afiliação
  • Augustemak de Lima LR; Universidade Federal de Santa Catarina. Florianópolis/SC/Brasil.
Arch Latinoam Nutr ; 58(4): 386-91, 2008 Dec.
Article em Es | MEDLINE | ID: mdl-19368300
The aim of the present study was twofold: a) to determine the agreement between bioelectrical impedance analysis (BIA) and dual energy X-ray absorptiometry (DEXA) for the estimation of skeletal muscle mass (SMM), and b) to analyze the predictive power of anthropometric variables and BIA for the prediction of SMM in the elderly. Sixty elderly men (61 to 80 years) from the southern region of Brazil were studied. Anthropometric variables (body weight and height) were measured, the resistance and hydration of fat-free tissues variables were determined by tetrapolar BIA (BF-310, Biodynamics). A whole body DEXA scan was also performed (Lunar Prodigy DF + 14319 Radiation and 7.52.002 DPX-L software). Differences between methods were analyzed using the t-test, analysis of residues and correlation coefficient. The predictive value of the anthropometric variables and BIA was evaluated by multiple linear regression. BIA overestimated SMM on average by 0.60 kg (sd = 1.59) when compared to DEXA, however, no statistical difference was observed (p > 0.05). There was a strong correlation between methods (r = 0.90; p < 0.01). Regression analysis demonstrated that the Ht2/ R variable explained 86% of the variation in SMM when adjusted for body weight and age, and this relationship did not depend on body fat, hydration of fat-free tissues or BMI. Thus, BIA as tested here is a valid method for the estimation of SMM in elderly men and its values can be best predicted using the regression model proposed, which included Ht2/R adjusted for body weight and age.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Composição Corporal / Envelhecimento / Absorciometria de Fóton / Músculo Esquelético Tipo de estudo: Prognostic_studies Limite: Aged / Aged80 / Humans / Male / Middle aged Idioma: Es Revista: Arch Latinoam Nutr Ano de publicação: 2008 Tipo de documento: Article País de publicação: Venezuela
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Composição Corporal / Envelhecimento / Absorciometria de Fóton / Músculo Esquelético Tipo de estudo: Prognostic_studies Limite: Aged / Aged80 / Humans / Male / Middle aged Idioma: Es Revista: Arch Latinoam Nutr Ano de publicação: 2008 Tipo de documento: Article País de publicação: Venezuela