[The skin flora: a source of the contamination of central venous catheters?]. / Flora cutânea: fonte de contaminação de cateteres venosos centrais?
Rev Paul Enferm
; 10(3): 103-7, 1991.
Article
em Pt
| MEDLINE
| ID: mdl-1843023
The authors studied the incidence of catheter related infection in 24 central venous catheter at the Departamento de Cirurgia da Faculdade de Ciências Médicas da Santa Casa de São Paulo. Skin and blood cultures were done in the first and fifth days and when the catheter were discharged. There were correlation between skin and catheter cultures in 33%. The results suggest that the skin flora is an important source of catheter related infection.
Buscar no Google
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Pele
/
Cateterismo Venoso Central
/
Contaminação de Equipamentos
Limite:
Female
/
Humans
/
Male
Idioma:
Pt
Revista:
Rev Paul Enferm
Ano de publicação:
1991
Tipo de documento:
Article
País de publicação:
Brasil