Your browser doesn't support javascript.
loading
Analysis of low content drug tablets by transmission near infrared spectroscopy: selection of calibration ranges according to multivariate detection and quantitation limits of PLS models.
Alcalà, Manel; León, Joshua; Ropero, Jorge; Blanco, Marcelo; Romañach, Rodolfo J.
Afiliação
  • Alcalà M; Analytical and Pharmaceutical Laboratory, Department of Chemistry, Faculty of Arts and Sciences, The University of Puerto Rico, PO BOX 9019, Mayagüez, Puerto Rico. manel@uprm.edu
J Pharm Sci ; 97(12): 5318-27, 2008 Dec.
Article em En | MEDLINE | ID: mdl-18351596
The content uniformity of low dose products is a major concern in the development of pharmaceutical formulations. Near infrared spectroscopy may be used to support the design and optimization of potent drug manufacturing processes through the analysis of blends and tablets in a relatively short time. A strategy for the selection of concentration ranges in the development of multivariate calibration is presented, evaluating the detection and quantitation limits of the obtained multivariate models. The strategy has been applied to the determination of an active principle in pharmaceutical tablets of low concentration (0-5%, w/w), using Fourier Transform Near Infrared (FT-NIR) transmission spectroscopy. The quantitation and detection limits decreased as the upper concentration level of the calibration models was reduced. The results obtained show that the selection of concentration ranges is a critical aspect during model design. The selection of wide concentration ranges with high levels is not recommended for the determination of analytes at minor levels (<1%, w/w), even when the concentration of interest is within the range of the model.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Comprimidos / Espectroscopia de Luz Próxima ao Infravermelho / Modelos Químicos Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: J Pharm Sci Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Porto Rico País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Comprimidos / Espectroscopia de Luz Próxima ao Infravermelho / Modelos Químicos Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: J Pharm Sci Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Porto Rico País de publicação: Estados Unidos