Your browser doesn't support javascript.
loading
Quantification of betamethasone in human plasma by liquid chromatography-tandem mass spectrometry using atmospheric pressure photoionization in negative mode.
Pereira, Alberto Dos Santos; Oliveira, Lina S O B; Mendes, Gustavo D; Gabbai, Jorge J; De Nucci, Gilberto.
Afiliação
  • Pereira Ados S; Galeno Research Unit, Latino Coelho St., 1301 Parque Taquaral, 13087-010 Campinas, SP, Brazil.
J Chromatogr B Analyt Technol Biomed Life Sci ; 828(1-2): 27-32, 2005 Dec 15.
Article em En | MEDLINE | ID: mdl-16221574
Betamethasone is a synthetic corticosteroid designed to exert a marked glucocorticoid activity. As the free alcohol, betamethasone finds widespread clinical applications related to its anti-inflammatory and immunosuppressant activity. In the present study, a fast, sensitive, robust method was developed for the determination and quantification of betamethasone in human plasma by liquid chromatography coupled with tandem mass spectrometry, using photospray ionization in negative mode. Betamethasone was extracted from 0.5 ml human plasma by liquid-liquid extraction (LLE) using chloramphenicol as internal standard. The method has a chromatographic run of 2.5 min using a C(18) analytical column (100 mm x 2.1 mm i.d.) and the linear calibration curve over the range was linear from 0.05 to 50 ng ml(-1) (r(2)>0.993). The between-run precision, based on the relative standard deviation replicate quality controls was 94.1% (0.15 ng ml(-1)), 90.7% (4.0 ng ml(-1)) and 97.2% (40 ng ml(-1)). The between-run accuracy for the above-mentioned concentrations was 11.9, 9.0 and 9.8%, respectively. The method herein described was employed in a bioequivalence study of two formulations of dexchlorpheniramine/betamethasone 2 mg/0.25 mg tablets.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Betametasona / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas por Ionização por Electrospray Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Brasil País de publicação: Holanda
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Betametasona / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas por Ionização por Electrospray Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Brasil País de publicação: Holanda