Your browser doesn't support javascript.
loading
Verapamil quantification in human plasma by liquid chromatography coupled to tandem mass spectrometry. An application for bioequivalence study.
do C Borges, Ney Carter; Mendes, Gustavo D; Barrientos-Astigarraga, Rafael E; Galvinas, Paulo; Oliveira, Celso H; De Nucci, Gilberto.
Afiliação
  • do C Borges NC; Department of Pharmacology, State University of Campinas, P.O. Box 6111, Campinas, SP, Brazil.
Article em En | MEDLINE | ID: mdl-16203182
An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection (LC-MS/MS) was developed for the determination of Verapamil in human plasma using Metoprolol as the internal standard. The analyte and internal standard were extracted from the plasma samples by liquid-liquid extraction and chromatographed on a C(8) analytical column. The mobile phase consisted of methanol-water (70:30; v/v)+12 mM formic acid. The method had a chromatographic total run time of 3.5 min and was linear within the range 1.00-500 ng/mL. Detection was carried out on a Micromass Quattro Ultima tandem mass spectrometer by multiple reaction monitoring (MRM). The intra-run imprecision was less than 5.1% calculated from the quality control (QC) samples, and 16.3% from the limit of quantification (LOQ). The accuracy determined from QC samples were between 92.9 and 103.1%, and 95.2 and 115.3% from LOQ. Concerning the inter-batch analysis, the imprecision was less than 5.8% and 17.3% from QC samples and LOQ, respectively. The accuracy varied between 98.2 and 100.8% from QC and it was 103.1% from LOQ. The protocol herein described was employed in a bioequivalence study of two tablet formulations of Verapamil.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Equivalência Terapêutica / Verapamil / Cromatografia Líquida / Espectrometria de Massas por Ionização por Electrospray Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Brasil País de publicação: Holanda
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Equivalência Terapêutica / Verapamil / Cromatografia Líquida / Espectrometria de Massas por Ionização por Electrospray Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Brasil País de publicação: Holanda