K-band EPR dosimetry: small-field beam profile determination with miniature alanine dosimeter.
Chen, Felipe; Graeff, Carlos F O; Baffa, Oswaldo.
Afiliação
  • Chen F; Departmento de Física e Matemática, FFCLRP-Universidade de São Paulo, Av. Bandeirantes, 3900, 14040-901, Ribeirão Preto-SP, Brazil.
Appl Radiat Isot ; 62(2): 267-71, 2005 Feb.
Article em En | MEDLINE | ID: mdl-15607460
The use of small-size alanine dosimeters presents a challenge because the signal intensity is less than the spectrometer sensitivity. K-band (24 GHz) EPR spectrometer seems to be a good compromise between size and sensitivity of the sample. Miniature alanine pellets were evaluated for small-field radiation dosimetry. Dosimeters of DL-alanine/PVC with dimensions of 1.5 mm diameter and 2.5 mm length with 5 mg mass were developed. These dosimeters were irradiated with 10 MV X-rays in the dose range 0.05-60 Gy and the first harmonic (1h) spectra were recorded. Microwave power, frequency and amplitude of modulation were optimized to obtain the best signal-to-noise ratio (S/N). For beam profile determination, a group of 25 dosimeters were placed in an acrylic device with dimensions of (7.5 x 2.5 x 1)cm3 and irradiated with a (3 x 3)cm2 10 MV X-rays beam field size. The dose at the central region of the beam was 20 Gy at a depth of 2.2 cm (build up for acrylic). The acrylic device was oriented perpendicular to the beam axis and to the gantry rotation axis. For the purposes of comparison of the spatial resolution, the beam profile was also determined with a radiographic film and 2 mm aperture optical densitometer; in this case the dose was 1 cGy. The results showed a similar spatial resolution for both types of dosimeters. The dispersion in dose reading was larger for alanine in comparison with the film, but alanine dosimeters can be read faster and more directly than film over a wide dose range.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiometria / Espectroscopia de Ressonância de Spin Eletrônica / Alanina / Micro-Ondas Tipo de estudo: Diagnostic_studies / Evaluation_studies Idioma: En Revista: Appl Radiat Isot Assunto da revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Brasil País de publicação: Reino Unido
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiometria / Espectroscopia de Ressonância de Spin Eletrônica / Alanina / Micro-Ondas Tipo de estudo: Diagnostic_studies / Evaluation_studies Idioma: En Revista: Appl Radiat Isot Assunto da revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Brasil País de publicação: Reino Unido