Your browser doesn't support javascript.
loading
A retrospective evaluation of rigid fixation in orthognathic surgery using a biodegradable self-reinforced (70L:30DL) polylactide.
Mazzonetto, R; Paza, A O; Spagnoli, D B.
Afiliação
  • Mazzonetto R; Division of Oral and Maxillofacial Surgery, Piracicaba Dental School, University of Campinas, Av. Limeira, n. 901, Bairro Areião, Piracicaba 13.414-900, SP, Brazil. renatomz@fop.unicamp.br
Int J Oral Maxillofac Surg ; 33(7): 664-9, 2004 Oct.
Article em En | MEDLINE | ID: mdl-15337179
OBJECTIVE: This study was designed to evaluate clinical and radiological evidence of osteotomy site healing in orthognathic surgery after rigid fixation using a biodegradable plating system. STUDY DESIGN: A follow up of 30 patients who underwent orthognathic surgery using a biodegradable self-reinforced (70L:30DL) polylactide plating system was presented. The follow-up schedule for all patients consisted of regular appointments at 1-180 days after surgery. Clinical evaluation involved notation of any abnormal swelling, infection, discoloration, or discharge at the osteotomy sites. Stability was evaluated by manual palpation. For radiographic evaluation, panoramic radiographs were taken immediately after surgery, and again at 7-180 days. The radiographs were analyzed for any visual changes in osteotomy fragments, resorptive changes in osteotomy fragments, callus formation, and union of the osteotomy segments. RESULTS: No clinical complications and no radiological changes in the osteotomy sites were observed. Regarding the clinical usefulness of the biodegradable fixation system, fixation at the time of operation was considered as excellent in all 30 cases. CONCLUSIONS: The conclusions of this study were that self-reinforced (70L:30DL) polylactide was considered to be comparable to other forms of rigid internal fixation for orthognathic surgery.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poliésteres / Osteotomia de Le Fort / Técnicas de Fixação da Arcada Osseodentária / Avanço Mandibular / Implantes Absorvíveis Tipo de estudo: Evaluation_studies / Guideline / Observational_studies Limite: Humans Idioma: En Revista: Int J Oral Maxillofac Surg Assunto da revista: ODONTOLOGIA Ano de publicação: 2004 Tipo de documento: Article País de afiliação: Brasil País de publicação: Dinamarca
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poliésteres / Osteotomia de Le Fort / Técnicas de Fixação da Arcada Osseodentária / Avanço Mandibular / Implantes Absorvíveis Tipo de estudo: Evaluation_studies / Guideline / Observational_studies Limite: Humans Idioma: En Revista: Int J Oral Maxillofac Surg Assunto da revista: ODONTOLOGIA Ano de publicação: 2004 Tipo de documento: Article País de afiliação: Brasil País de publicação: Dinamarca