Your browser doesn't support javascript.
loading
[Biphasic low-energy internal cardioversion in atrial fibrillation induced during electrophysiologic study]. / Cardioversión eléctrica interna con baja energía y curva bifásica en fibrilación auricular inducida durante el estudio electrofisiológico.
Karmelic, C F; Cambón, A M; González, R.
Afiliação
  • Karmelic CF; Departamento de Enfermedades Cardiovasculares, Laboratorio de Electrofisiología Cardíaca, Pontificia Universidad Católica, Santiago, Chile. elecfisi@med.puc.cl
Rev Esp Cardiol ; 53(3): 337-43, 2000 Mar.
Article em Es | MEDLINE | ID: mdl-10712966
INTRODUCTION: Atrial fibrillation is observed in 10% of electrophysiological studies. Previous studies have shown the efficacy of biphasic low energy internal cardioversion to restore sinus rhythm. We studied the efficacy and safety of low-energy internal cardioversion and the biphasic curve, in sustained atrial fibrillation (>15 min) during electrophysiologic procedures. MATERIALS AND METHODS: From January 1997 to August 1998, 320 patients underwent an electrophysiological study. An internal cardioversion was done on those patients who developed sustained atrial fibrillation. We delivered biphasic shocks between electrodes-catheters positioned in the right atrium and the coronary sinus. Increasing energy was applied until restoration of sinus rhythm or a maximum of 10 joules were achieved with no result. A right ventricle electrode was used to synchronize the V wave and for temporary pacing. RESULTS: Thirty one episodes of sustained atrial fibrillation were observed in 26 patients (1,23 episodes/patient) and a mean of 2,58 internal cardioversions were applied per every patient. Sinus rhythm was restored in twenty three patients. The mean energy delivered was 4.1 joules. The mean time for the recovery was 3,200 ms. Temporary pacing was used in 16% of the patients for up to 1 minute. No AV blocks were observed. CONCLUSIONS: Internal cardioversion successfully restored sinus rhythm in 88.5% of the patients who presented sustained atrial fibrillation (88.5%). Temporary pacing was necessary for the treatment of postsinus shock pauses.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Cardioversão Elétrica / Estimulação Cardíaca Artificial Tipo de estudo: Diagnostic_studies / Etiology_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: Es Revista: Rev Esp Cardiol Ano de publicação: 2000 Tipo de documento: Article País de afiliação: Chile País de publicação: Espanha
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Cardioversão Elétrica / Estimulação Cardíaca Artificial Tipo de estudo: Diagnostic_studies / Etiology_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: Es Revista: Rev Esp Cardiol Ano de publicação: 2000 Tipo de documento: Article País de afiliação: Chile País de publicação: Espanha