O papel da superfície moderadamente rugosa e quimicamente modificada em um protocolo de carga precoce: uma revisão de literatura / The role of a moderately rough and chemically modified implant surface in an early loading protocol: a literature review
Dent. press implantol
; 9(2): 76-88, Apr.-Jun.2015. ilus
Article
em Pt
| LILACS
| ID: lil-790545
Biblioteca responsável:
BR1366.1
RESUMO
Realizar uma revisão de literatura, com base nas evidências científicas atualmente disponíveis, a respeito dos períodos iniciais do reparo ósseo em torno de implantes com superfície moderadamente rugosa e quimicamente modificada (MRQM). Para a revisão da literatura, foi realizada uma pesquisa eletrônica via PubMed, utilizando, para a seleção dos artigos, uma combinação das palavras-chave osseointegration, bone-to-implant contact, wettability, chemically modified surface e bone healing. Foram considerados estudos experimentais in vitro, em modelos animais e em humanos, abrangendo as características físico-químicas, mecanismos biológicos e eventos histológicos iniciais relacionados à superfície MRQM. Estudos experimentais reportam uma maior aposição óssea e ancoragem à superfície quimicamente modificada, nos estágios iniciais do reparo ósseo, em modelos animais. Esses resultados experimentais foram validados por estudos clínicos prospectivos, estudos de mensuração da estabilidade do implante com análise de frequência de ressonância (RFA), perfis de expressão gênica e histológicos temporais em modelos humanos. Dentro das limitações desse estudo da superfície MRQM, é possível sugerir que a alta energia da superfície e molhabilidade aumentada influenciam positivamente na formação óssea nos períodos iniciais do reparo ósseo...
ABSTRACT
The aim of this study was to accomplish a literature review, based on currently available evidence, about the early periods of bone integration around endosseous implants with moderately rough and chemically modified surface (MRCM). The review was performed through an electronic survey via PubMed, using a combination of keywords, including osseointegration, bone-to-implant contact, wettability, chemically modified surface and bone healing. Experimental in vitro studies, in animal models and in humans, covering physicochemical characteristics, biological mechanisms and initial histological events related to MRCM implant surface were considered. Experimental studies report higher bone apposition and better bone anchorage to MRCM surfaces during early stages of bone healing in animal models. These experimental results were validated by prospective clinical studies, studies measuring implant stability with resonance frequency analysis, gene expression profiles and temporal histological studies in human models. Within the limitations of this MRCM surface study, it is suggested that high surface energy and increased wettability positively influence bone formation in the initial periods of bone repair...
Palavras-chave
Buscar no Google
Coleções:
01-internacional
Base de dados:
LILACS
Assunto principal:
Implantes Dentários
/
Osseointegração
/
Molhabilidade
Tipo de estudo:
Prognostic_studies
Limite:
Animals
/
Humans
Idioma:
Pt
Revista:
Dent. press implantol
Assunto da revista:
ODONTOLOGIA
Ano de publicação:
2015
Tipo de documento:
Article
País de afiliação:
Brasil
País de publicação:
Brasil