Efeito do laser de baixa potência na dor após a montagem do aparelho ortodôntico / Effect of low level laser for pain relief after the first orthodontic archwires placement
Rev. Assoc. Paul. Cir. Dent
; 69(4): 421-425, 2015. ilus, tab, graf
Article
em Pt
| LILACS
| ID: lil-778746
Biblioteca responsável:
BR97.1
RESUMO
Objetivo:
avaliar clinicamente a eficácia da Terapia de Laser de Baixa Potência (TLBP) no alívio da dor após a instalação do aparelho ortodôntico e primeiro arco.Materiais e Métodos:
90 voluntários receberam aparelho fixo e colocação do primeiro arco ortodôntico. Foram randomicamente divididos em três grupos Grupo 1- Controle (n=30), Grupo 2 - Placebo (n=30) e Grupo 3 - Laser (n=30). Foi realizada a TLBP infravermelho (810 nm) com 100 mW de potência e dose de 6 J/cm2 divididas em quatro aplicações por dente. A dor foi avaliada utilizando Escala Visual Analógica (EVA). Os dados obtidos foram submetidos à análise estatística por meio de teste de Kruskal- Wallis (α=0,05).Resultados:
Em todos os grupos analisados a dor iniciou-se após 2 horas, houve um pico de dor entre 12 horas e 48 horas e sua diminuição ocorreu em sete dias. O Grupo 3 (Laser) apresentou todos os valores de dor menores em relação aos valores observados nos outros grupos. Houve diferença estatisticamente significante (p<0,05) da dor pós-operatória entre 12 e 48 horas (momento de pico de dor) para o grupo 3 em relação aos grupos 1 e 2.Conclusão:
A TLBP mostrou-se eficiente para a redução da dor após a colocação do aparelho fixo e primeiro arco ortodôntico...ABSTRACT
Objective:
The aim of this study was to clinically evaluate Low Level Laser Therapy (LLLT) as a method of reducing pain after the first orthodontic archwire placement. Materials andMethods:
90 volunteers received metal braces and the first archwire. They were randomly distributed over three different treatment groups Group 1- (n=30) Control, patients did not received any LLLT; Group 2- (n=30) Placebo, the LLLT was simulated, the laser was turned off; Group 3- (n=30) Laser patients received LLLT, infra-red with 810 nm wave length and 100 mW power, and it was used 6 J/cm2 as total dose per tooth, divided into four times of 1.5 J/cm2 per 12 seconds per point. Pain intensity experienced was evaluated by a Visual Analogue Scale. Data were tabulated and analyzed through Biostat 4.0 software. Means and standard deviations were calculated and a Kruskal-Wallis statics test was performed (Dunns method) (α=0.05).Results:
It was possible to observe that the pain started 2 hours after treatment was initiated in the three groups. Higher pain levels occurred between 12 and 48 hours, and pain reduction occurred in 7 days. Group 3 (Laser) presented lower pain data values than the other groups. There was a statistically significant difference (p<0.05) among post operating pain in times T3, T4 and T5 between group 3 and groups 1 and 2.Conclusion:
LLLT reduced the pain after orthodontics braces and archwires placement...
Buscar no Google
Coleções:
01-internacional
Base de dados:
LILACS
Assunto principal:
Ortodontia
/
Terapia com Luz de Baixa Intensidade
/
Arco Dental
Tipo de estudo:
Clinical_trials
Limite:
Humans
Idioma:
Pt
Revista:
Rev. Assoc. Paul. Cir. Dent
Assunto da revista:
ODONTOLOGIA
Ano de publicação:
2015
Tipo de documento:
Article
País de afiliação:
Brasil
País de publicação:
Brasil