Efeito do laser de baixa potência na dor após a montagem do aparelho ortodôntico / Effect of low level laser for pain relief after the first orthodontic archwire’s placement
Pinheiro, Sergio Luiz; Agustinho, Maria Madalena Silva; De Martin, Alexandre Sigrist; Bueno, Carlos Eduardo da Silveira.
Afiliação
  • Pinheiro, Sergio Luiz; Pontifícia Universidade Católica de Campinas. Faculdade de Odontologia. Campinas. BR
  • Agustinho, Maria Madalena Silva; Universidade São Leopoldo Mandic. Faculdade de Odontologia. Campinas. BR
  • De Martin, Alexandre Sigrist; Universidade São Leopoldo Mandic. Faculdade de Odontologia. Campinas. BR
  • Bueno, Carlos Eduardo da Silveira; Pontifícia Universidade Católica de Campinas. Faculdade de Odontologia. Campinas. BR
Rev. Assoc. Paul. Cir. Dent ; 69(4): 421-425, 2015. ilus, tab, graf
Article em Pt | LILACS | ID: lil-778746
Biblioteca responsável: BR97.1
RESUMO

Objetivo:

avaliar clinicamente a eficácia da Terapia de Laser de Baixa Potência (TLBP) no alívio da dor após a instalação do aparelho ortodôntico e primeiro arco.

Materiais e Métodos:

90 voluntários receberam aparelho fixo e colocação do primeiro arco ortodôntico. Foram randomicamente divididos em três grupos Grupo 1- Controle (n=30), Grupo 2 - Placebo (n=30) e Grupo 3 - Laser (n=30). Foi realizada a TLBP infravermelho (810 nm) com 100 mW de potência e dose de 6 J/cm2 divididas em quatro aplicações por dente. A dor foi avaliada utilizando Escala Visual Analógica (EVA). Os dados obtidos foram submetidos à análise estatística por meio de teste de Kruskal- Wallis (α=0,05).

Resultados:

Em todos os grupos analisados a dor iniciou-se após 2 horas, houve um pico de dor entre 12 horas e 48 horas e sua diminuição ocorreu em sete dias. O Grupo 3 (Laser) apresentou todos os valores de dor menores em relação aos valores observados nos outros grupos. Houve diferença estatisticamente significante (p<0,05) da dor pós-operatória entre 12 e 48 horas (momento de pico de dor) para o grupo 3 em relação aos grupos 1 e 2.

Conclusão:

A TLBP mostrou-se eficiente para a redução da dor após a colocação do aparelho fixo e primeiro arco ortodôntico...
ABSTRACT

Objective:

The aim of this study was to clinically evaluate Low Level Laser Therapy (LLLT) as a method of reducing pain after the first orthodontic archwire placement. Materials and

Methods:

90 volunteers received metal braces and the first archwire. They were randomly distributed over three different treatment groups Group 1- (n=30) Control, patients did not received any LLLT; Group 2- (n=30) Placebo, the LLLT was simulated, the laser was turned off; Group 3- (n=30) Laser patients received LLLT, infra-red with 810 nm wave length and 100 mW power, and it was used 6 J/cm2 as total dose per tooth, divided into four times of 1.5 J/cm2 per 12 seconds per point. Pain intensity experienced was evaluated by a Visual Analogue Scale. Data were tabulated and analyzed through Biostat 4.0 software. Means and standard deviations were calculated and a Kruskal-Wallis statics test was performed (Dunn’s method) (α=0.05).

Results:

It was possible to observe that the pain started 2 hours after treatment was initiated in the three groups. Higher pain levels occurred between 12 and 48 hours, and pain reduction occurred in 7 days. Group 3 (Laser) presented lower pain data values than the other groups. There was a statistically significant difference (p<0.05) among post operating pain in times T3, T4 and T5 between group 3 and groups 1 and 2.

Conclusion:

LLLT reduced the pain after orthodontics braces and archwires placement...
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: LILACS Assunto principal: Ortodontia / Terapia com Luz de Baixa Intensidade / Arco Dental Tipo de estudo: Clinical_trials Limite: Humans Idioma: Pt Revista: Rev. Assoc. Paul. Cir. Dent Assunto da revista: ODONTOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil
Buscar no Google
Coleções: 01-internacional Base de dados: LILACS Assunto principal: Ortodontia / Terapia com Luz de Baixa Intensidade / Arco Dental Tipo de estudo: Clinical_trials Limite: Humans Idioma: Pt Revista: Rev. Assoc. Paul. Cir. Dent Assunto da revista: ODONTOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil