Your browser doesn't support javascript.
loading
Fusión de imágenes y protección de hipocampo para el tratamiento de metástasis cerebrales con radioterapia / Image fusion and hippocampus protection in radiotherapy treatment of brain metastases
Alwers, Elizabeth; Bobadilla, Iván; Vásquez, Jaider; Cifuentes, Javier; Torres, Felipe.
Afiliação
  • Alwers, Elizabeth; Centro de Control de Cáncer Ltda. Bogotá. CO
  • Bobadilla, Iván; Centro de Control de Cáncer Ltda. Bogotá. CO
  • Vásquez, Jaider; Centro de Control de Cáncer Ltda. Bogotá. CO
  • Cifuentes, Javier; Centro de Control de Cáncer Ltda. Bogotá. CO
  • Torres, Felipe; Centro de Control de Cáncer Ltda. Bogotá. CO
Rev. colomb. cancerol ; 19(2): 119-122, abr.-jun. 2015. ilus, tab
Article em Es | LILACS | ID: lil-765561
Biblioteca responsável: CO40.1
RESUMEN
Las imágenes de simulación obtenidas mediante TAC son actualmente el estándar para uso en los sistemas de planificación de haces externos empleados en los tratamientos de radioterapia. Sin embargo, una de las limitaciones es su bajo contraste y poca especificidad para la identificación y caracterización de lesiones tumorales y algunas estructuras a nivel de sistema nervioso central. Los nuevos algoritmos implementados en los sistemas de planificación de radioterapia permiten realizar la fusión de imágenes de RM con TAC de simulación, definir y proteger estructuras como el hipocampo, buscando administrar dosis bajas en esta zona, lograr mayores dosis a los volúmenes tumorales y disminuir los efectos secundarios derivados de tratamientos holoencefálicos con radioterapia. En este artículo se presentan las imágenes correspondientes a esta técnica de tratamiento.
ABSTRACT
CT simulation images are the current standard in external beam radiotherapy planning systems. However, the limitations of images obtained from CT scanning include their low contrast and low specificity in the identification and characterization of tumor lesions and some central nervous system structures. The new algorithms implemented in radiotherapy planning systems allow image fusion to be performed using MRI images and CT simulation images. It also allows structures like the hippocampus to be defined and protected, by administering lower Radiosurgery; doses to this area and higher doses to the tumor volume, thus decreasing side effects arising from whole brain radiotherapy treatment. Images corresponding to this treatment technique are presented in this article.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Imageamento por Ressonância Magnética / Tomografia Computadorizada de Emissão / Radiocirurgia / Cérebro Limite: Humans Idioma: Es Revista: Rev. colomb. cancerol Assunto da revista: Neoplasias / Oncologia Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Colômbia País de publicação: Colômbia

Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Imageamento por Ressonância Magnética / Tomografia Computadorizada de Emissão / Radiocirurgia / Cérebro Limite: Humans Idioma: Es Revista: Rev. colomb. cancerol Assunto da revista: Neoplasias / Oncologia Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Colômbia País de publicação: Colômbia