Your browser doesn't support javascript.
loading
Aplicación del test de 6 minutos en personas con obesidad, en un programa de actividad física / Using the 6-minute walking test with obese people engaged in a physical activity program
Ramírez-Cardona, Lorena; Valenzuela-Cazes, Alejandra.
Afiliação
  • Ramírez-Cardona, Lorena; Asociación Argentina de Kinesiología y Asociación Internacional de Salud. Buenos Aires. AR
  • Valenzuela-Cazes, Alejandra; Universidade nacional da Colômbia. Faculdade de Medicina. Bogotá. CO
Rev. salud pública ; Rev. salud pública;16(4): 569-574, jul.-ago. 2014. ilus, tab
Article em Es | LILACS | ID: lil-735158
Biblioteca responsável: BR1.1
RESUMEN
Objetivo Identificar la aplicabilidad del test de 6 minutos en 22 adultos con obesidad (12 mujeres y 10 hombres) en un programa de actividad física de 6 meses. Métodos Estudio longitudinal que utilizo el test de 6 minutos como evaluación de la capacidad cardiopulmonar, en un programa de actividad física en personas con diferentes grados de obesidad.

Resultados:

La primera evaluación del test de 6 minutos se encontró que los intervalos que presentaron mayor frecuencia fueron 439,7-468,7=27,3 % (6) y 468,71-487,71=27,3 % (6). En La evaluación final al programa de actividad física el intervalo que presento mayor frecuencia fue 463,01-501,01=45,5 % (10), sin presentarse manifestaciones clínicas y/o físicas para su interrupción en las personas evaluadas. Conclusiones Se encontró que el test de 6 minutos es una herramienta de evaluación y seguimiento en personas con obesidad, en el programa de actividad física. Se recalca seguir el protocolo para su realización.(AU)
ABSTRACT
Objective Evaluating the applicability of the 6-minute walking test (6MWT) on 22 obese adults (12 women and 10 men) engaged in a physical activity program lasting 6 months. Methodology This longitudinal study involved using the 6MWT for evaluating cardiorespiratory capacity in people having different levels of obesity who were engaged in a physical activity program. Results The first set of 6MWT results revealed that the intervals having the highest frequency were 439.7-468.7=27.3 % (6) and 468.71-487.71=27.3 % (6). The 6MWT result at the end of the evaluation showed that the interval having the highest frequency was 463.01-501.01=45.5 % (10), without presenting clinical and/or physical signs which could have interrupted the test on the people being evaluated. Conclusions This study showed the 6MWT to be applicable as an evaluation and tracking tool for obese people engaged in a physical activity program. It should be stressed that the 6MWT protocol must be closely followed when evaluating physical endurance.(AU)
Assuntos
Palavras-chave
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Resistência Física / Atividade Motora / Obesidade Tipo de estudo: Guideline / Observational_studies / Risk_factors_studies Limite: Humans Idioma: Es Revista: Rev. salud pública Assunto da revista: SAUDE PUBLICA Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Argentina / Colômbia País de publicação: Colômbia
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Resistência Física / Atividade Motora / Obesidade Tipo de estudo: Guideline / Observational_studies / Risk_factors_studies Limite: Humans Idioma: Es Revista: Rev. salud pública Assunto da revista: SAUDE PUBLICA Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Argentina / Colômbia País de publicação: Colômbia