Viabilidade de dentes decíduos artificiais para mensuração eletrônica do comprimento de trabalho dos canais radiculares / Viability of artificial primary teeth for electronic working length determination
Pesqui. bras. odontopediatria clín. integr
; 13(1): 83-87, mar. 2013.
Article
em Pt
| LILACS
| ID: lil-724212
Biblioteca responsável:
BR1264.1
RESUMO
Objetivo:
viabilizar a utilização de dentes decíduos artificiais com polpa e condutos radiculares em pesquisas ôin vitroõ com o uso do localizador apical Root ZX II.Método:
foram selecionados 20 molares decíduos artificiais que apresentavam três condutos radiculares e não apresentavam trincas, fraturas ou defeitos de fabricação. Foi feita abertura coronária, acesso aos condutos, patência foraminal e mensuração dos canais radiculares por meio de método visual e eletrônico. A mensuração no método visual (G1- controle) foi realizada introduzindo a lima no ponto da cúspide de referência até a lima atingir o forame apical. No método eletrônico (G2- experimental), os dentes foram inseridos em alginato e a lima inserida no canal radicular até o localizador indicar o ápice. As mensurações foram realizadas em triplicata. As médias das medidas em milímetros foram submetidas ao teste de correlação de Pearson no programa Biostat 2.0 com valor de significância de 5%.Resultados:
as medidas observadas pelo método eletrônico apresentaram correlação com os resultados obtidos pelo método visual (r Pearson = 0,9490; p = 0,0000).Conclusão:
os dentes decíduos artificiais podem ser utilizados em pesquisas ôin vitroõ com o localizador apical Root ZX II...ABSTRACT
Objective:
To allow the use of artificial primary teeth with pulp and root canals for in vitro studies with the Root ZX II electronic apex locator.Method:
Twenty artificial primary molars with three root canals and no cracks, fractures or fabrication defects were selected. After coronal opening, access to the canals was gained, foramen patency waschecked and direct and electronic working length determination was performed. For direct visual working length determination (Group 1 ?control), the file was introduced into the canal from the reference cusp until its tip was visible at the apical foramen. For the electronic working length determination (Group 2 ? experimental), the teeth were embedded in alginate and the file was introduced into the canal until the electronica locator indicated the apex. The measurements were made in triplicate. The means (in mm) were subjected to Pearson?s correlation coefficient test using the Biostat 2.0 software. The significance level was set at 5%.Results:
The electronic measurements correlated with the direct visual measurements (r=0.9490; p=0.0000).Conclusion:
Artificial primary teeth can be used for in vitro studies with the Root ZX II electronic apex locator...Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
LILACS
Assunto principal:
Tratamento do Canal Radicular
/
Dente Artificial
/
Dente Decíduo
/
Técnicas In Vitro
Limite:
Humans
Idioma:
Pt
Revista:
Pesqui. bras. odontopediatria clín. integr
Assunto da revista:
ODONTOLOGIA
Ano de publicação:
2013
Tipo de documento:
Article
País de afiliação:
Brasil
/
Canadá
País de publicação:
Brasil