Your browser doesn't support javascript.
loading
Adhesion and formation of tags from MTA Fillapex compared with AH Plus® cement
Baechtold, Marina Samara; Mazaro, Ana Flávia; Crozeta, Bruno Monguilott; Leonardi, Denise Piotto; Tomazinho, Flávia Sens Fagundes; Baratto-Filho, Flares; Haragushiku, Gisele Aihara.
Afiliação
  • Baechtold, Marina Samara; Positivo University. Department of Dentistry. Curitiba. BR
  • Mazaro, Ana Flávia; Positivo University. Department of Dentistry. Curitiba. BR
  • Crozeta, Bruno Monguilott; Positivo University. Department of Dentistry. Curitiba. BR
  • Leonardi, Denise Piotto; Positivo University. Department of Dentistry. Curitiba. BR
  • Tomazinho, Flávia Sens Fagundes; Positivo University. Department of Dentistry. Curitiba. BR
  • Baratto-Filho, Flares; Positivo University. Department of Dentistry. Curitiba. BR
  • Haragushiku, Gisele Aihara; Positivo University. Department of Dentistry. Curitiba. BR
RSBO (Impr.) ; 11(1): 71-76, Jan.-Mar. 2014. ilus, graf, tab
Article em En | LILACS | ID: lil-718009
Biblioteca responsável: BR97.1
ABSTRACT
Introduction and

Objective:

The aim of this study was two-fold 1) to evaluate, in vitro, the shear bond strength of two sealers by push-out test and 2) to assess the failures after displacement. Additionally, the formation of tags was observed by SEM. Material and

methods:

Forty mandibular premolars were selected and the canals were subjected to biomechanical preparation with rotary instruments. These specimens were divided into two groups according to the sealer (n = 20) GI - MTA Fillapex and GII - AH Plus. All roots were filled with sealer only, without gutta-percha. After a period corresponding to three times the setting time of the sealer, the roots were sectioned transversely into slices of 1 mm thickness, to obtain one slice from the cervical third, to be used in the push-out test. Following, two slices of each group were randomly chosen for ultrastructural analysis by scanning electron microscopy (SEM). The data obtained in shear bond strength test were subjected to statistical analysis.

Results:

AH Plus cement exhibited higher shear bond strength values (1.332±0.75 MPa) than MTA Fillapex (0.071±0.07 MPa), with statistically significant differences.

Conclusion:

MTA Fillapex has a low bond strength with less formation of tags than AH Plus.
Palavras-chave
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Idioma: En Revista: RSBO (Impr.) Assunto da revista: ODONTOLOGIA Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Idioma: En Revista: RSBO (Impr.) Assunto da revista: ODONTOLOGIA Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil