OBJETIVO:
Elaborar e validar o questionário de qualidade de vida na versão do idioma português.MÉTODOS:
O questionário "Cataract TyPESpecification" modificado foi desenvolvido especificamente para avaliar a qualidade de vida pós-cirurgia de catarata. O questionário avaliou 10 itens status funcionais por meio de 18 perguntas. Foi aplicado por um único examinador, com o objetivo de graduar a satisfação visual de 0 a 10 (0 muito insatisfeito; 5 neutro; 10 muito satisfeito). Houve estudo prospectivo comparativo, não randomizado, que incluiu 142 olhos de 71 pacientes com catarata da Universidade de São Paulo. A avaliação oftalmológica contou com medida da acuidade visual para longa, intermediária e curta distâncias, sem correção e com a melhor correção óptica e questionário de satisfação. Foi submetido a um questionário de satisfação quanto à acuidade visual e fenômenos fóticos. Todos os exames foram realizados com 6 meses de pós-operatório.RESULTADOS:
A média de idade dos pacientes foi de 60,7 ± 6,6 anos no grupo Tecnis, 63,1 ± 4,4 anos no grupo Restor e 63,7 ± 4,2 anos no grupo SN60AT/SN60WF. A acuidade visual para perto não-corrigida e a corrigida para longe foram estatisticamente superiores nos grupos Restor® e Tecnis® comparadas ao grupo SN60AT/SN60WF (p<0,001). Não houve diferença estatística entre os grupos quando comparadas a acuidade visual para longe não-corrigida e a melhor corrigida (p=0,56). O questionário de satisfação apresentou maior independência de óculos a favor da Tecnis® (9,3/10) e Restor® (8,7/10), mas com mais queixas de halos (Restor® 18,8%; Tecnis® 21,7%) e glare (Restor® 25%; Tecnis® 26,1%) do que no grupo SN60AT/SN60WF.CONCLUSÃO:
A Restor® e Tecnis® apresentaram melhor acuidade visual para perto do que o grupo SN60AT/SN60WF. As lentes Restor® e Tecnis® apresentaram maior satisfação na visão de perto e independência do uso de óculos e fenômenos fóticos do que as lentes monofocais...ABSTRACT
PURPOSE:
Development and validation of quality of life questionnaire in pseudophakic patients in Portuguese.METHODS:
The modified Cataract TyPESpecification questionnaire was specifically developed to assess quality of life after cataract surgery, functional status evaluated with 10 items and contains 18 questions. All questions were applied by a single examiner, with the goal of graduating visual satisfaction from 0 to 10 (0 means very dissatisfied, 5 neutral, 10 very satisfied).This prospective comparative study included 142 eyes of 71 patients in Sao Paulo University. The ophthalmologic evaluation performed included near, intermediate and distance corrected and uncorrected visual acuity and quality of life questionaire. The minimum follow-up was 6 months.RESULTS:
The mean age of patients was 60.7± 6.6 years in theTecnis®MF, 63.1 ±4.4 years in-groupRestor®63.7±4.2 years in-group SN60AT/SN60WF. Uncorrected and distance-corrected near visual acuity were statistically higher in theRestor® and Tecnis® groups compared to the SN60AT/SN60WF group (p<0.001). There were no statistical differences between groups comparing uncorrected and best-corrected distance visual acuity (p=0.56). Satisfaction questionnaire showed high glasses independence fortheTecnis®MF (9.3 /10) and Restor® (8.7 /10), but with more unsatisfied of halos (18.8% Restor®, Tecnis®21, 7%) and glare (Restor® 25%;Tecnis®26.1%) than the group SN60AT/SN60WF.CONCLUSION:
Cataract patients who received multifocal (Restor®; Tecnis®MF) IOLs at time of surgery obtained better uncorrected and distance corrected near visual acuity and reported better overall vision, less limitation in visual function, less spectacle dependency, and more glare or halo than those who received monofocal (SN60AT; SN60WF) IOLs. Cataract TyPESpecification questionnaire was a strong predictor of change in patient satisfaction caused by cataract surgery.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
LILACS
Assunto principal:
Qualidade de Vida
/
Extração de Catarata
/
Acuidade Visual
/
Satisfação do Paciente
/
Implante de Lente Intraocular
Tipo de estudo:
Clinical_trials
/
Observational_studies
/
Risk_factors_studies
Aspecto:
Patient_preference
Limite:
Female
/
Humans
/
Male
Idioma:
Pt
Revista:
Rev. bras. oftalmol
Assunto da revista:
OFTALMOLOGIA
Ano de publicação:
2013
Tipo de documento:
Article
País de afiliação:
Brasil
País de publicação:
Brasil