Avaliacao comparativa entre os metodos objetivo e subjetivo em laminas coradas pela imuno-histoquimica / Comparative assessment between objective and subjective methods in slides stained by immunohistochemistry
Braz. j. otorhinolaryngol. (Impr.)
; Braz. j. otorhinolaryngol. (Impr.);79(6): 704-708, Nov-Dec/2013. tab, graf
Article
em Pt
| LILACS
| ID: lil-697681
Biblioteca responsável:
BR1.1
RESUMO
Métodos objetivos de avaliação são frequentemente cobrados em estudos científicos. Exames histológicos com coloração imuno-histoquímica podem ser avaliados por meio de fotometria. OBJETIVO:
Comparar este método objetivo com a avaliação subjetiva realizada por três observadores independentes, utilizando lâminas de colesteatoma adquirido da orelha média.MÉTODO:
Foram selecionadas um total de 54 imagens de colesteatomas imuno-histoquimicamente coradas pelos anticorpos anti-TNF-R2 (32 lâminas) e anti-TGF-α; (22 lâminas). O anticorpo secundário utilizado nos dois grupos foi o Max Polimer Detection System (Kit Novo Link, Novocastra®, UK). As amostras foram processadas por um scanner digital de lâminas (modelo ScanScope - Aperio). As áreas selecionadas foram submetidas à análise por fotometria.RESULTADOS:
A avaliação objetiva por fotometria foi comparada com a avaliação subjetiva por três observadores e submetidas à análise estatística. A análise estatística revelou reprodutibilidade moderada (K valores entre 0,41 e 0,60) para os dois grupos.CONCLUSÃO:
O presente estudo demonstrou que as características irregulares das lâminas de colesteatoma da orelha média coradas pela imuno-histoquímica impossibilita a sua adequada avaliação objetiva, enquanto a avaliação subjetiva por observadores experientes se mostrou mais confiável. .ABSTRACT
Objective methods of assessment are often required in scientific studies. Histological tests with immunohistochemical staining can be assessed by photometry. OBJECTIVE:
To compare this objective method with the subjective evaluation performed by three independent examiners, using slides of acquired middle ear cholesteatomas.METHOD:
We selected a total of 54 cholesteatoma images, immunohistochemically stained by anti-TNF-R2 (32 slides) and anti-TGF-α, (22 slides). The secondary antibody used in the two groups was the Max Polymer Detection System (Novo Link Kit, Novocastra®, UK). The samples were processed by a digital slide scanner (ScanScope - Aperio). The selected sites were analyzed by photometry.RESULTS:
The objective assessment by photometry was compared with the subjective evaluation by three examiners and subjected to statistical analysis. The Statistical analysis revealed moderate reproducibility (K values between 0.41 and 0.60) for both groups.CONCLUSION:
Our study showed that the irregular characteristics of middle ear cholesteatoma slides stained by immunohistochemistry prevents its proper objective evaluation, while the subjective assessment by experienced examiners was more reliable. .Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
LILACS
Assunto principal:
Autoanticorpos
/
Fator de Crescimento Transformador alfa
/
Colesteatoma da Orelha Média
/
Receptores Tipo II do Fator de Necrose Tumoral
Tipo de estudo:
Health_technology_assessment
/
Prognostic_studies
Limite:
Humans
Idioma:
Pt
Revista:
Braz. j. otorhinolaryngol. (Impr.)
Assunto da revista:
OTORRINOLARINGOLOGIA
Ano de publicação:
2013
Tipo de documento:
Article
País de afiliação:
Brasil
País de publicação:
Brasil