Your browser doesn't support javascript.
loading
Thermal analysis of bulk filled composite resin polymerization using various light curing modes according to the curing depth and approximation to the cavity wall
Journal of Applied Oral Science; Chang, Hoon-Sang; Cho, Kyu-Jeong; Park, Su-Jung; Lee, Bin-Na; Hwang, Yun-Chan; Oh, Won-Mann; Hwang, In-Nam.
Afiliação
  • Chang, Hoon-Sang; s.af
  • Cho, Kyu-Jeong; s.af
  • Park, Su-Jung; s.af
  • Lee, Bin-Na; s.af
  • Hwang, Yun-Chan; s.af
  • Oh, Won-Mann; s.af
  • Hwang, In-Nam; s.af
J. appl. oral sci ; J. appl. oral sci;21(4): 293-299, Jul-Aug/2013. tab, graf
Article em En | LILACS | ID: lil-684563
Biblioteca responsável: BR1.1
ABSTRACT

OBJECTIVE:

The purpose of this study was to investigate the polymerization temperature of a bulk filled composite resin light-activated with various light curing modes using infrared thermography according to the curing depth and approximation to the cavity wall. MATERIAL AND

METHODS:

Composite resin (AeliteFlo, Bisco, Schaumburg, IL, USA) was inserted into a Class II cavity prepared in the Teflon blocks and was cured with a LED light curing unit (Dr's Light, GoodDoctors Co., Seoul, Korea) using various light curing modes for 20 s. Polymerization temperature was measured with an infrared thermographic camera (Thermovision 900 SW/TE, Agema Infra-red Systems AB, Danderyd, Sweden) for 40 s at measurement spots adjacent to the cavity wall and in the middle of the cavity from the surface to a 4 mm depth. Data were analyzed according to the light curing modes with one-way ANOVA, and according to curing depth and approximation to the cavity wall with two-way ANOVA.

RESULTS:

The peak polymerization temperature of the composite resin was not affected by the light curing modes. According to the curing depth, the peak polymerization temperature at the depth of 1 mm to 3 mm was significantly higher than that at the depth of 4 mm, and on the surface. The peak polymerization temperature of the spots in the middle of the cavity was higher than that measured in spots adjacent to the cavity wall.

CONCLUSION:

In the photopolymerization of the composite resin, the temperature was higher in the middle of the cavity compared to the outer surface or at the internal walls of the prepared cavity. .
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Resinas Compostas / Cura Luminosa de Adesivos Dentários / Lâmpadas de Polimerização Dentária / Polimerização / Temperatura Alta Idioma: En Revista: J. appl. oral sci Assunto da revista: ODONTOLOGIA Ano de publicação: 2013 Tipo de documento: Article / Project document País de publicação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Resinas Compostas / Cura Luminosa de Adesivos Dentários / Lâmpadas de Polimerização Dentária / Polimerização / Temperatura Alta Idioma: En Revista: J. appl. oral sci Assunto da revista: ODONTOLOGIA Ano de publicação: 2013 Tipo de documento: Article / Project document País de publicação: Brasil