Coloraciones histológicas vs. Microscopia electrónica de transmisión para detección de biopelículas en pacientes con rinosinusitis crónica en el Hospital Universitario de La Samaritana, en el año 2011 / Histological stainings versus Electronic Microscopy Biofilms transmission for detecting biofilms in patients with chronic rhinosinusitis in the Samaritanas Hospital. 2011
Acta otorrinolaringol. cir. cabeza cuello
; 40(2): 107-113, abr.-jun. 2012. ilus
Article
em Es
| LILACS
| ID: lil-682819
Biblioteca responsável:
CO361.9
RESUMEN
Objetivo:
Determinar la concordancia entre Microscopia de Luz vs. Microscopia Electrónica de Transmisión, para la detección de biopelículas en pacientes con rinosinusitis crónica.Diseño:
Estudio de concordancia. Materiales ymétodos:
Analizamos 34 muestras de pacientes llevados a cirugía endoscópica funcional por rinosinusitis crónica. Fueron procesadas para valoración mediante microscopia de luz usando hematoxilina-eosina, gram, ácido peryódico de Schiff, Giemsa y Microscopia Electrónica de Transmisión (MET).Resultados:
No se identificaron biopelículas en ninguna de las muestras analizadas bajo MET; estos resultados concuerdan con los obtenidos con las coloraciones histológicas hematoxilina-eosina (H-E), Gram, Giemsa y ácido peryódico de Schiff (PAS), y muestran una concordancia absoluta con el test de Kappa para resultados negativos del 100%ABSTRACT
Objectives:
Determine the concordance between light microscopy vs. Transmission Electron Microscopy for the detection of biofilms in patients with Chronic Rhinosinusitis.Design:
Materials andMethods:
We analyzed 34 samples of patients who underwent Functional Endoscopic Surgery for Chronic Rhinosinusitis. These were processed for evaluation by light microscopy using Hematoxylin-Eosin, Gram, periodic acid- Schiff, Giemsa and Transmission Electron Microscopy (TEM).Results:
Biofilm was not identified in any of the samples analyzed under transmission electron microscopy (TEM), these results are consistent with the results obtained with hematoxylin-eosin histological staining (HE), Gram, Giemsa and periodic acid-Schiff (PAS), showing an absolute concordance with Kappa test of 100% for negative results.Conclusion:
There is a high correlation between the findings observed between the TEM and light microscopy for the negative resultsPalavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
LILACS
Assunto principal:
Sinusite
/
Microscopia Eletrônica
/
Técnicas Histológicas
/
Biofilmes
Tipo de estudo:
Prognostic_studies
Limite:
Humans
Idioma:
Es
Revista:
Acta otorrinolaringol. cir. cabeza cuello
Assunto da revista:
Cirurgia
/
OTORRINOLARINGOLOGIA
/
Otorrinolaringopatias
/
Cirurgia
Ano de publicação:
2012
Tipo de documento:
Article
País de afiliação:
Colômbia
País de publicação:
Colômbia