Avaliação da liberação de flúor de compósitos ortodônticos: superBond Instant® e Color Change® / Assessment of release of fluoride composites orthodontic: superBond Instant® and Color Change®
Rev. odontol. Univ. Cid. São Paulo (Online)
; 24(3)set.-dez. 2012. tab, graf
Article
em Pt
| LILACS, BBO
| ID: lil-661327
Biblioteca responsável:
BR1.1
RESUMO
Introdução:
O objetivo deste estudo é testar a hipótese de que não há diferença no desempenho de compósitos ortodônticos entre si quanto à liberação de flúor.Métodos:
Os materiais foram divididos em 3 grupos 2 compósitos ortodônticos utilizados para colagem de bráquetes ortodônticos Grupo SI (SuperBond Instant, OrthoSource) e Grupo CC (Color Change, OrthoSource) e 1 cimento de ionômero de vidro (CIV) convencional utilizado para cimentação de bandas ortodônticas; Grupo S (Sumo, OrthoSource), como controle. A liberação de flúor foi medida durante 28 dias (1h, 24h, 1, 3, 7, 14, 21 e 28 dias), através de eletrodo íon seletivo conectado a um analisador de íons. Os dados foram submetidos aos testes não paramétricos de Kruskal-Wallis e de Mann-Whitney, a um nível de significância de 5%.Resultados:
Os resultados evidenciaram que os materiais atingiram o pico máximo de liberação de flúor com 24h após presa inicial. Houve diferença estatística entre os grupos SI e CC com o grupo S em todos os tempos avaliados (p < 0.05). Houve diferença estatística entre os grupos SI e CC nos tempos de 1h, 24h, 3, 7, 14 e 21 dias (p < 0.05).Conclusão:
A hipótese foi rejeitada. O compósito Color Change apresentou desempenho melhor comparado ao SuperBond Instant, porém ambos apresentaram uma liberação de flúor pouco expressiva comparados ao CIV convencional.ABSTRACT
Introduction:
The objective of this study is to test the hypothesis that there is no difference in performance of orthodonticcomposites in terms of their fluoride release.Methods:
The materials were divided into three groupstwo composites used for orthodontic Bonding of orthodontic brackets Group SI (Instant SuperBond, Ortho-Source) and Group CC (Color Change, OrthoSource) and a glass ionomer cement (GIC) used for conventionalcementing orthodontic bands Group S (Sumo, OrthoSource) as the control. Fluoride release was measuredduring 28 Days (1h, 24h, 1, 3, 7, 14, 21 and 28 Days), by ion selective electrode connected to an ion analyzer.The data were subjected to nonparametric tests of Kruskal-Wallis and Mann-Whitney, with a significance levelof 5%.Results:
The results showed that the materials reached the peak of fluoride release after 24 hours afterinitial set. Statistical difference between groups SI and DC with the group S at all times evaluated (p <0.05).Statistical difference between groups SI and CC in 1h, 24h, 3, 7, 14 and 21 Days (p <0.05).Conclusion:
Thehypothesis was rejected. Color Change composite performance was better compared to SuperBond Instant, butboth had a very expressive fluoride release compared to conventional GIC.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
BBO
/
LILACS
Assunto principal:
Compômeros
/
Flúor
/
Cimentos de Ionômeros de Vidro
Idioma:
Pt
Revista:
Rev. odontol. Univ. Cid. São Paulo (Online)
Assunto da revista:
ODONTOLOGIA
Ano de publicação:
2012
Tipo de documento:
Article
País de afiliação:
Brasil
País de publicação:
Brasil