Avaliação in vitro da microdureza de novos compósitos em diferentes espessuras / In vitro microhardness evaluation of new composite resins in different thickness
J. Health Sci. Inst
; 25(4)out.-dez. 2007. graf, tab
Article
em Pt
| LILACS
| ID: lil-655193
Biblioteca responsável:
BR1151.1
RESUMO
Introdução - Com o surgimento de novos compósitos, há um grande interesse pelo conhecimento de suas propriedades mecânicas. O objetivo deste trabalho foi avaliar in vitro a microdureza Vickers de quatro compósitos (Z 250, Natural Look, Epricord e Clearfil Majesty), em espessuras de 0, 1, 2, 3 e 4 mm. Material e Métodos - Vinte corpos de prova para cada compósito foram confeccionados em matrizes circulares de polipropileno pretas e a resina inserida em porção única e fotopolimerizada por 40s. A seguir, foram armazenados por uma semana, a 37°C, a seco, em recipientes escuros. A microdureza Vickers foi avaliada por meio de um microdurômetro digital HMV (Shimatzu, Japão), com auxílio do software CAM-Wins, utilizando carga de 50gf por 45s. Cinco medidas foram obtidas por corpo de prova. A análise estatística utilizou o teste ANOVA e teste de Tukey, com um nível de significância de 5%. Resultados - Após a análise de variância observou-se diferença significante entre as resinas (F = 235,07), entre as espessuras (F = 331,10) e para a interação resina X espessura (F = 14,95). O valor de Tukey foi 12,12. Conclusões - Os valores de microdureza diminuíram com o aumento da espessura da resina composta, para todas as resinas utilizadas. A resina Z 250 possibilitou o seu uso em incrementos de até 3 mm, a Natural Look até 2 mm e as Epricord e a Clearfil Majesty até 1 mm apenas.
ABSTRACT
Introduction - Due to new dental composite resins are arising, there is a great interest in clarifying their mechanic's properties. The aim of this study was to investigate the in vitro microhardness of four composite resins (Z 250, Natural Look, Epricord and Clearfil Majesty) with different thicknesses 0, 1, 2, 3 and 4 mm. Material and Methods - Twenty specimens of each composite resin were made on matrices of black polypropylene with cylindrical holes in which a single portion of the resin was applied and photopolymerized for 40s. Following, they were stored for a week, at 37°C in a dry and dark chamber. Vickers microhardness was measured using a digital microdurometer HMV (Shimatzu, Japan) with the CAM-wins software, using 50gf for 45s.Five measurements were made for each specimen. The data were statistically analyzed using ANOVA and Tukey tests (p < 0.05). Results - After the analysis of variance, significant differences were detected among the composite resins (F = 235.07), among their thicknesses (F = 331.10), and between the resin x thickness interaction (F = 14.95). The Tukey value was 12.12. Conclusions - The results revealed that an increase of the resin thickness produced a decrease in microhardness, for all composite resins analyzed. Increments of composite resins should not exceed 3 mm for Z 250, 2 mm for Natural Look, and only 1 mm for Epricord and Clearfil Majesty.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
LILACS
Assunto principal:
Resinas Compostas
/
Polimerização
/
Testes de Dureza
Limite:
Humans
Idioma:
Pt
Revista:
J. Health Sci. Inst
Assunto da revista:
MEDICINA
Ano de publicação:
2007
Tipo de documento:
Article
País de afiliação:
Brasil
País de publicação:
Brasil