Your browser doesn't support javascript.
loading
La prueba de Hartmann en ciencias de la visión / Hartmann test in vision science
Mejía Barbosa, Yobani.
Afiliação
  • Mejía Barbosa, Yobani; Universidad Nacional. CO
Cienc. tecnol. salud vis. ocul ; 10(1): 159-165, ene.-jul. 2012. tab, graf, ilus
Article em Es | LILACS | ID: lil-653316
Biblioteca responsável: CO149.2
RESUMEN
En este artículo se muestran tres aplicaciones de la prueba de Hartmann en Ciencias de la Visión, desarrolladas en el laboratorio de diseño óptico del Departamento de Física de la Universidad Nacional de Colombia lensómetro para lentes de adición progresiva, topógrafo corneal y aberrómetro tipo Hartmann-Shack. Primero se describe brevemente la prueba clásica de Hartmann para espejos astronómicos y luego se presentan tres variaciones de la prueba de Hartmann para optometría y oftalmología. En cada caso se describe el sistema óptico empleado y la geometría para deducir la aberración de frente de onda a partir de las aberraciones de rayo (patrones de Hartmann). En los tres casos se obtienen relaciones matemáticas similares, por lo que el frente de onda se puede determinar en cada caso empleando el mismo método de integración. Posteriormente, se calculan las cantidades de interés, a saber en lensometría, los mapas de potencia refractiva cilíndrica y esférica; en topografía, el mapa de curvatura tangencial; y en aberrometría, el mapa de elevación de frente de onda y la psf. Finalmente, se hace un breve comentario sobre la implementación de la prueba de Hartmann por parte de algunas compañías comerciales.
ABSTRACT
In this paper, we present three applications of the Hartmann test in vision science, developed atthe optical design laboratory of the Physics Department at the National University of Colombialensmeter for progressive addition lenses, corneal topography, and Hartmann-Shack aberrometer.First we briefly describe the classical Hartmann test for astronomical mirrors, and later threevariations of the Hartmann test for optometry and ophthalmology are done. In each case the opticalsystem and geometry used to derive the wavefront aberration from ray aberrations (Hartmann patterns) are described. In all three cases similar mathematical relationships are obtained, so that the wavefront can be determined in each case using the same method of integration. Afterwards,the quantities of interest are calculated in order to find out in lensometry, maps of cylindrical and spherical refractive power; in topography, the map of tangential curvature; and in aberrometry,the wavefront elevation map and psf. Finally, a brief comment is made on the implementation of the Hartmann test by some commercial companies.
Assuntos
Palavras-chave
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Topografia da Córnea / Aberrometria Idioma: Es Revista: Cienc. tecnol. salud vis. ocul Assunto da revista: INFORMATICA MEDICA / OFTALMOLOGIA / OPTOMETRIA / TECNOLOGIA Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Colômbia País de publicação: Colômbia
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Topografia da Córnea / Aberrometria Idioma: Es Revista: Cienc. tecnol. salud vis. ocul Assunto da revista: INFORMATICA MEDICA / OFTALMOLOGIA / OPTOMETRIA / TECNOLOGIA Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Colômbia País de publicação: Colômbia