Your browser doesn't support javascript.
loading
O uso de implantes orbitários de polietileno granulado de ultra-alto peso molecular no reparo de cavidades anoftálmicas / The use of orbital ultra-high molecular weight granulated polyethylene implants in the anophthalmic socket repair
Soranz Filho, João Edward; Mendes, Gustavo; Takahira, Regina Kiomi; Schellini, Silvana Artioli; Pellizzon, Cláudia Helena.
Afiliação
  • Soranz Filho, João Edward; Universidade Estadual Paulista Júlio de Mesquita Filho. Botucatu. BR
  • Mendes, Gustavo; Universidade Estadual Paulista Júlio de Mesquita Filho. Botucatu. BR
  • Takahira, Regina Kiomi; Universidade Estadual Paulista Júlio de Mesquita Filho. Botucatu. BR
  • Schellini, Silvana Artioli; Universidade Estadual Paulista Júlio de Mesquita Filho. Faculdade de Medicina de Botucatu. Botucatu. BR
  • Pellizzon, Cláudia Helena; Universidade Estadual Paulista Júlio de Mesquita Filho. Botucatu. BR
Rev. bras. oftalmol ; 71(4): 227-232, jul.-ago. 2012. ilus, tab
Article em Pt | LILACS | ID: lil-650654
Biblioteca responsável: BR1.2
RESUMO

OBJETIVO:

Alterações oculares, em especial a perda de volume nas cavidades evisceradas, promovem uma série de modificações ao paciente tanto funcional do órgão quanto psicológica e estética. Para tanto a procura de um material de baixo custo e com biocompatibilidade tem sido uma constante na literatura. Portanto, esse trabalho teve como objetivo testar experimentalmente implante de polietileno granulado de ultra-alto peso molecular, material de baixo custo, em órbitas de coelhos submetidos à evisceração cirúrgica em vários tempos experimentais, onde foram avaliados aspectos macroscópicos e microscópicose de toxicidade sistêmica do material.

MÉTODOS:

Para esse estudo foram utilizados coelhos Oryctolaguscuniculus submetidos à evisceração do globo ocular direito e posteriormente implantados com esfera de polietileno granulado de ultra-alto peso molecular e analisados por 15, 30, 90 e 180 dias pós-implante, com parâmetros macro, microscópios e bioquímicos. Os animais controles foram submetidos ao mesmo procedimento sem, entretanto a colocação do implante.

RESULTADOS:

Os resultados desse trabalho mostram que o material utilizado no implante de cavidade não apresenta alteração significativa nos parâmetros de peso e bioquímicos quando comparados ao grupo controle. O material implantado apresentou uma grande interação com o tecido do hospedeiro.

CONCLUSÃO:

Os resultados indicam que implante de polietileno granulado de alto peso molecular desenvolvido por uma indústria nacional tem alto potencial para se realizar testes em humanos.
ABSTRACT

OBJECTIVE:

Ocular changes in special due to volume loss in eviscerated cavities promote several psychological aesthetic and functional alterations to patients. For this reason, searches aiming at finding a material of low cost and biocompatibility have been constantly carried out. Test experimentally the implants constituted of ultra-high molecular weight granular polyethylene oflow cost, in orbits of rabbits subjected to surgical evisceration in several experimental times, evaluating the macro and microscope aspects besides the systemic toxicity of the material.

METHODS:

In this study we eviscerated the right ocular globe of rabbits of the species Oryctolaguscuniculus, implanted posteriorly a sphere of granular polyethylene of ultrahigh molecular weight and analysed the effects through macro, micro and biochemical parameters during 15, 30, 90 and 180 days after implantation.The control group were submitted the same procedure without the implants.

RESULTS:

This paper shows that the material used in the cavity does not present significant alteration in the weight and in the biochemistry of the animal; a good assimilation (integration) of the material implanted by the tissue formed was observed inside the implant.

CONCLUSION:

The results indicate that ultra-high molecular weight granular polyethylene implant developed by a national industry presents excellent integration in the model used supporting further use in tests with humans.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Polietilenos / Anoftalmia / Exenteração Orbitária / Implantes Orbitários / Olho Artificial Tipo de estudo: Observational_studies / Prognostic_studies Limite: Animals Idioma: Pt Revista: Rev. bras. oftalmol Assunto da revista: OFTALMOLOGIA Ano de publicação: 2012 Tipo de documento: Article / Project document País de afiliação: Brasil País de publicação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Polietilenos / Anoftalmia / Exenteração Orbitária / Implantes Orbitários / Olho Artificial Tipo de estudo: Observational_studies / Prognostic_studies Limite: Animals Idioma: Pt Revista: Rev. bras. oftalmol Assunto da revista: OFTALMOLOGIA Ano de publicação: 2012 Tipo de documento: Article / Project document País de afiliação: Brasil País de publicação: Brasil