Evaluación no lineal de dos postes diferentes / Nonlinear evaluation of two different posts
Rev. Fac. Odontol. Univ. Antioq
; 23(2): 240-255, jun. 2012. graf, tab
Article
em Es
| LILACS
| ID: lil-641190
Biblioteca responsável:
CO66.1
RESUMEN
Introducción:
los dientes tratados endodóncicamente que van a ser rehabilitados con coronas y que han perdido parte de su estructura dental, necesitan de un poste prefabricado o colado para que ayude a la retención de la restauración final y así el diente puedarecuperar la funcionalidad y la estética. La literatura reporta cuándo utilizar un poste colado o prefabricado, pero no es contundente cuál distribuye mejor los esfuerzos, cuál material o forma de poste es mejor y si el módulo de elasticidad tiene o no relación con la distribución de las cargas a lo largo del eje axial del diente.Métodos:
se hicieron dos modelos en SolidWorks de un incisivo central superior con todassus estructuras de soporte, uno con un poste colado y otro con un poste prefabricado, además de una corona completamente cerámica. Mediante un análisis de elementos finitos se cargaron dichos dientes a 200, 400, 600 y 800 N para llevarlos hasta la plasticidad.Resultados:
200 y 400 N ambos postes mostraron diferente distribución de esfuerzos sin afectar la restauración o la raíz dental.Conclusiones:
a cargas masticatorias normales, ambos postes son predecibles para rehabilitar un diente que necesita de la incorporación de un poste.ABSTRACT
Introduction:
endodontically treated teeth that will be restored with crowns and which have lost part of their dental structure need a cast post or a prefabricated post to improve final restoration retention and therefore to be able to regain their functionality andaesthetics. The literature suggests when to use a cast or prefabricated post, but it is not conclusive in terms of which one has a better stress distribution, which post material or shape is better, or whether their modulus of elasticity is related to load distribution along thetooths axis.Methods:
by using Solid Works, two models of a maxillary central incisor with all its supporting structures were made, one with a cast post and another one with a prefabricated post plus an all-ceramic crown. By means of finite element analysis both teeth were subjected to loads of 200, 400, 600 and 800 N up to reaching their plasticity.Results:
at 200 and 400 N, both posts showed different stress distribution patterns without altering the restoration or the tooths root.Conclusions:
at normal masticatory loads, both posts are likely to restore a tooth that needs addition of a post.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
LILACS
Assunto principal:
Coroa do Dente
/
Endodontia
Idioma:
Es
Revista:
Rev. Fac. Odontol. Univ. Antioq
Assunto da revista:
ODONTOLOGIA
Ano de publicação:
2012
Tipo de documento:
Article
País de afiliação:
Colômbia
País de publicação:
Colômbia