Primary fixation of mini slings: a comparative biomechanical study in vivo
Palma, Paulo; Siniscalchi, Rodrigo Teixeira; Maciel, Luiz Carlos; Bigozzi, Miguel Angel; Dal Fabbro, Inacio; Riccetto, Cassio.
Afiliação
  • Palma, Paulo; s.af
  • Siniscalchi, Rodrigo Teixeira; s.af
  • Maciel, Luiz Carlos; s.af
  • Bigozzi, Miguel Angel; s.af
  • Dal Fabbro, Inacio; University of Campinas. Biological Materials Laboratory. Sao Paulo. BR
  • Riccetto, Cassio; s.af
Int. braz. j. urol ; 38(2): 258-266, Mar.-Apr. 2012. ilus, tab
Article em En | LILACS | ID: lil-623341
Biblioteca responsável: BR1.1
ABSTRACT
INTRODUCTION AND

OBJECTIVES:

The mini sling concept for stress urinary incontinence is an anatomical approach that involves placing a midurethral low-tension tape anchored to the obturator internus muscles bilaterally. They overcome the blind passage of long needles and all the related complications. There are many different devices available and because these are outpatient procedures, primary fixation plays an important role in the outcome. The objective is to evaluate the primary fixation of the various devices of attachment of the commercially available mini-slings through biomechanical tests. MATERIALS AND

METHODS:

A total of 45 Wistar rats were divided in 3 groups of 15 rats each. They underwent 5 subcutaneous implantation of different mini slings and one polipropilene mesh (control), as follows TVT-Secur® (Gynecare, USA), Type 1 polypropylene mesh (control); Ophira Mini Sling System® (Promedon, Argentina), Tissue Fixation System® (TFS PTY, Australia), Zipper Sling® and "T device" (Prosurg, USA). The abdominal wall was removed on bloc at different times after implant for biomechanical evaluation, which consisted in application of unidirectional force to the extremity of the fixation system or mesh, until it was completely removed from the tissue using a tension meter (Nexygen 3.0 Universal Testing Machine - LLOYD Instruments). The force was measured in Newtons (N).

RESULTS:

There was significant difference in the resistance to extraction among the different fixation systems. At 7 days the Ophira Mini Sling System® presented the best fixation and "T dispositive" the worst.

CONCLUSION:

Ophira mini sling System® presented the best primary fixation at 7º, 14º and 30º days. The impact of this feature in the clinical setting needs to be verified.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Uretra / Incontinência Urinária por Estresse / Slings Suburetrais Tipo de estudo: Evaluation_studies Limite: Animals Idioma: En Revista: Int. braz. j. urol Assunto da revista: UROLOGIA Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Uretra / Incontinência Urinária por Estresse / Slings Suburetrais Tipo de estudo: Evaluation_studies Limite: Animals Idioma: En Revista: Int. braz. j. urol Assunto da revista: UROLOGIA Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil