Accuracy of three electronic apex locators in the presence of different irrigating solutions
Carvalho, Ana Laura Pion; Moura-Netto, Cacio; Moura, Abilio Albuquerque Maranhão de; Marques, Márcia Martins; Davidowicz, Harry.
Afiliação
  • Carvalho, Ana Laura Pion; s.af
  • Moura-Netto, Cacio; s.af
  • Moura, Abilio Albuquerque Maranhão de; s.af
  • Marques, Márcia Martins; s.af
  • Davidowicz, Harry; s.af
Braz. oral res ; 24(4): 394-398, Oct.-Dec. 2010. tab
Article em En | LILACS | ID: lil-569216
Biblioteca responsável: BR1.1
ABSTRACT
The present study compared the accuracy of three electronic apex locators (EALs) - Elements Diagnostic®, Root ZX® and Apex DSP® - in the presence of different irrigating solutions (0.9 percent saline solution and 1 percent sodium hypochlorite). The electronic measurements were carried out by three examiners, using twenty extracted human permanent maxillary central incisors. A size 10 K file was introduced into the root canals until reaching the 0.0 mark, and was subsequently retracted to the 1.0 mark. The gold standard (GS) measurement was obtained by combining visual and radiographic methods, and was set 1 mm short of the apical foramen. Electronic length values closer to the GS (± 0.5 mm) were considered as accurate measures. Intraclass correlation coefficients (ICCs) were used to verify inter-examiner agreement. The comparison among the EALs was performed using the McNemar and Kruskal-Wallis tests (p < 0.05). The ICCs were generally high, ranging from 0.8859 to 0.9657. Similar results were observed for the percentage of electronic measurements closer to the GS obtained with the Elements Diagnostic® and the Root ZX® EALs (p > 0.05), independent of the irrigating solutions used. The measurements taken with these two EALs were more accurate than those taken with Apex DSP®, regardless of the irrigating solution used (p < 0.05). It was concluded that Elements Diagnostic® and Root ZX® apex locators are able to locate the cementum-dentine junction more precisely than Apex DSP®. The presence of irrigating solutions does not interfere with the performance of the EALs.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Irrigantes do Canal Radicular / Técnicas In Vitro / Preparo de Canal Radicular / Ápice Dentário / Odontometria Limite: Humans Idioma: En Revista: Braz. oral res Assunto da revista: ODONTOLOGIA Ano de publicação: 2010 Tipo de documento: Article País de publicação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Irrigantes do Canal Radicular / Técnicas In Vitro / Preparo de Canal Radicular / Ápice Dentário / Odontometria Limite: Humans Idioma: En Revista: Braz. oral res Assunto da revista: ODONTOLOGIA Ano de publicação: 2010 Tipo de documento: Article País de publicação: Brasil