Your browser doesn't support javascript.
loading
Comparative study of two commercially pure titanium casting methods
Rodrigues, Renata Cristina Silveira; Faria, Adriana Claudia Lapria; Orsi, Iara Augusta; Mattos, Maria da Gloria Chiarello de; Macedo, Ana Paula; Ribeiro, Ricardo Faria.
Afiliação
  • Rodrigues, Renata Cristina Silveira; s.af
  • Faria, Adriana Claudia Lapria; s.af
  • Orsi, Iara Augusta; s.af
  • Mattos, Maria da Gloria Chiarello de; s.af
  • Macedo, Ana Paula; s.af
  • Ribeiro, Ricardo Faria; s.af
J. appl. oral sci ; J. appl. oral sci;18(5): 487-492, Sept.-Oct. 2010. graf
Article em En | LILACS | ID: lil-564183
Biblioteca responsável: BR1.1
ABSTRACT
The interest in using titanium to fabricate removable partial denture (RPD) frameworks has increased, but there are few studies evaluating the effects of casting methods on clasp behavior.

OBJECTIVE:

This study compared the occurrence of porosities and the retentive force of commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) removable partial denture circumferential clasps cast by induction/centrifugation and plasma/vacuum-pressure. MATERIAL AND

METHODS:

72 frameworks were cast from CP Ti (n=36) and Co-Cr alloy (n=36; control group). For each material, 18 frameworks were casted by electromagnetic induction and injected by centrifugation, whereas the other 18 were casted by plasma and injected by vacuum-pressure. For each casting method, three subgroups (n=6) were formed 0.25 mm, 0.50 mm, and 0.75 mm undercuts. The specimens were radiographed and subjected to an insertion/removal test simulating 5 years of framework use. Data were analyzed by ANOVA and Tukey's to compare materials and cast methods (α=0.05).

RESULTS:

Three of 18 specimens of the induction/centrifugation group and 9 of 18 specimens of plasma/vacuum-pressure cast presented porosities, but only 1 and 7 specimens, respectively, were rejected for simulation test. For Co-Cr alloy, no defects were found. Comparing the casting methods, statistically significant differences (p<0.05) were observed only for the Co-Cr alloy with 0.25 mm and 0.50 mm undercuts. Significant differences were found for the 0.25 mm and 0.75 mm undercuts dependent on the material used. For the 0.50 mm undercut, significant differences were found when the materials were induction casted.

CONCLUSION:

Although both casting methods produced satisfactory CP Ti RPD frameworks, the occurrence of porosities was greater in the plasma/vacuum-pressure than in the induction/centrifugation method, the latter resulting in higher clasp rigidity, generating higher retention force values.
Assuntos
Palavras-chave
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Titânio / Ligas de Cromo / Técnica de Fundição Odontológica / Retenção de Dentadura Idioma: En Revista: J. appl. oral sci Assunto da revista: ODONTOLOGIA Ano de publicação: 2010 Tipo de documento: Article / Project document País de publicação: Brasil
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Titânio / Ligas de Cromo / Técnica de Fundição Odontológica / Retenção de Dentadura Idioma: En Revista: J. appl. oral sci Assunto da revista: ODONTOLOGIA Ano de publicação: 2010 Tipo de documento: Article / Project document País de publicação: Brasil