Your browser doesn't support javascript.
loading
Influência do desenho do implante na micromovimentação de implantes imediatos com carga imediata: análise multivariada em elementos finitos / Influence of implant design on the micromovement of immediately placed and loaded implants: a multivariate finite element analysis
Pessoa, Roberto Sales e; Muraru, Luiza; Vaz, Luis Geraldo; Pereira, Gilberto Nunes; Sloten, Jos Vander; Jaecques, Siegfried V. N..
Afiliação
  • Pessoa, Roberto Sales e; Universidade Estadual Paulista. Faculdade de Odontologia de Araraquara. Araraquara. BR
  • Muraru, Luiza; University College Kempen. Geel. BE
  • Vaz, Luis Geraldo; Universidade Estadual Paulista. Faculdade de Odontologia de Araraquara. Departamento de Materiais Dentários e Prótese. Araraquara. BR
  • Pereira, Gilberto Nunes; Centro Universitário da Fundação Educacional de Barretos. Barretos. BR
  • Sloten, Jos Vander; Katholieke Universiteit Leuven. Leuven. BE
  • Jaecques, Siegfried V. N.; Katholieke Universiteit Leuven. Leuven. BE
Article em Pt | LILACS, BBO | ID: lil-561130
Biblioteca responsável: BR1354.1
RESUMO
O objetivo deste trabalho foi avaliar a influência do desenho do implante nas micromovimentações de implantes imediatos com carga imediata. Modelos em elementos finitos de um alvéolo de extração de um incisivo central superior e quatro desenhos de implantes de conexão interna, disponíveis comercialmente (SIN SW®, 3i Certain®, Nobel ReplaceTM e RN synOcta® ITI Standard), com diâmetros e comprimentos semelhantes foram construídos. Cargas de 50, 100 e 200 N foram aplicadas sobre os implantes. ANOVA com nível de 95% de significância foi utilizada para avaliar os dados da micromovimentação dos implantes. O design do implante influencia significativamente (31,21%) a micromovimentação de implantes imediatos com carga imediata. Não obstante, a intensidade da carga aplicada (68,80%) é o fator mais importante na estabilidade dos implantes neste protocolo.
ABSTRACT
The purpose of this paper was to evaluate the influence of different implant designs on the micromovements of immediately placed implants. CT-based finite element models comprising an upper central incisor socket and four commercially available internal connection implant designs (SIN SW®, 3i Certain®, Nobel ReplaceTM, and RN synOcta® ITI Standard) of comparable diameter and length were constructed. 50, 100 and 200N magnitude loads were applied over the implant. ANOVA at 95% level of significance was used to evaluate bone to implant relative displacement (micromovements). The implant design (68,80%) greatly influences the micromovement of immediately placed implants. However, the loading magnitude (68,80%) is the most important factor regarding the implant stability in this protocol.
Assuntos
Palavras-chave
Texto completo: 1 Coleções: 01-internacional Base de dados: BBO / LILACS Assunto principal: Fenômenos Biomecânicos / Implantes Dentários / Osseointegração Tipo de estudo: Prognostic_studies Idioma: Pt Revista: Innov. implant. j., biomater. esthet. (Impr.) Assunto da revista: CIRURGIA GERAL / ODONTOLOGIA / ORTODONTIA Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Bélgica / Brasil País de publicação: Brasil
Texto completo: 1 Coleções: 01-internacional Base de dados: BBO / LILACS Assunto principal: Fenômenos Biomecânicos / Implantes Dentários / Osseointegração Tipo de estudo: Prognostic_studies Idioma: Pt Revista: Innov. implant. j., biomater. esthet. (Impr.) Assunto da revista: CIRURGIA GERAL / ODONTOLOGIA / ORTODONTIA Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Bélgica / Brasil País de publicação: Brasil