Fiabilidad del CSV 1000 para evaluar la función de sensibilidad al contraste en infantes entre los siete y diez años / Reliability of CSV 1000 to evaluate the role of contrast sensitivity in children between seven and ten years
León, Alejandro; Estrada, Jorge; Quiroz, Diana; Bedoya, Diana.
Afiliação
  • León, Alejandro; Fundación Universitaria del Área Andina. Pereira. CO
  • Estrada, Jorge; Fundación Universitaria del Área Andina. Pereira. CO
  • Quiroz, Diana; Fundación Universitaria del Área Andina. Pereira. CO
  • Bedoya, Diana; Fundación Universitaria del Área Andina. Pereira. CO
Article em Es | LILACS | ID: lil-560863
Biblioteca responsável: CO149.2
RESUMEN

Objetivo:

determinar la concordancia entre observadores para medir la función de sensibilidad al contraste empleando el test CSV 1000E en un grupo de infantes entre los siete a diez años.

Metodología:

fueron evaluados cincuenta niños (cien ojos) visualmente sanos empleando el CSV 1000E. Cada infante fue evaluado por dos evaluadores el mismo día con una diferencia de 30 minutos entre evaluaciones.

Resultados:

la curva de sensibilidad al contraste promedio fue normal, aunque superior hacia las frecuencias espaciales altas, al ser comparada con un estudio similar (López, 2003). La concordancia obtenida fue muy pobre –coeficiente de correlación concordancia de Lin (pc<0.90)– para todas las frecuencias espaciales, debido a la falta de precisión del test; los límites de acuerdo fueron más amplios a los publicados en otra investigación (Pomerance & Evans, 1994).

Conclusiones:

los resultados encontrados muestran que el test tiene una baja concordancia, lo que indicaría una pobre validez para medir la función de sensibilidad al contraste en niños.
ABSTRACT
The purpose of this trial was determinate the test retest reliability between evaluators to measurement contrast sensitivity function using the CSV 1000E test in children between 7-10 years.

Methods:

fifty visually-healthy children were tested using the CSV1000E. Each children was seen by 2 evaluators the same day, thirty minutes apart from each evaluations.

Results:

the contrast sensitivity curve function was normal, although it was higher for high spatial frequencies when compared to that was it found in another trial (López, 2003). test retest reliability was poor (pc<0.90) for all spatial frequencies because the CSV 1000 precision was low, 95 por ciento limits of agreement were wider than found in another research project (Pomerance y Evans, 1994).

Conclusions:

the results have shown that CSV 1000 had low agreement, means this test has poor reliability to assess contrast sensitivity function in children.
Assuntos
Palavras-chave
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Sensibilidades de Contraste / Acuidade Visual Tipo de estudo: Diagnostic_studies Limite: Child Idioma: Es Revista: Cienc. tecnol. salud vis. ocul Assunto da revista: INFORMATICA MEDICA / OFTALMOLOGIA / OPTOMETRIA / TECNOLOGIA Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Colômbia País de publicação: Colômbia
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Sensibilidades de Contraste / Acuidade Visual Tipo de estudo: Diagnostic_studies Limite: Child Idioma: Es Revista: Cienc. tecnol. salud vis. ocul Assunto da revista: INFORMATICA MEDICA / OFTALMOLOGIA / OPTOMETRIA / TECNOLOGIA Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Colômbia País de publicação: Colômbia