Falhas de fundição nas infraestruturas de próteses ferulizadas sobre implantes: ensaio in vitro / Casting failures in denture structures with ferrule attachment to implants: an in vitro test
RGO (Porto Alegre)
; 57(2): 165-172, abr.-jun. 2009. ilus
Article
em Pt
| LILACS, BBO
| ID: lil-522790
Biblioteca responsável:
BR541.1
RESUMO
Objetivo:
Avaliar, por meio de análise metalográfica, a qualidade de dois processos de fundição em dois metais utilizados rotineiramente em próteses ferulizadas sobre implantes.Métodos:
Uma base de alumínio foi usinada para que, sobre ela, fossem esculpidos os padrões de cera de oito barras, tipo protocolo, com 3 mm de diâmetro e 6 cm de extensão. Foram fundidas quatro barras de Titânio com a técnica do arco voltaico e quatro em liga de Cobalto-Cromo pela técnica de gás e ar por meio de maçarico. As oito barras finalizadas foram cortadas, incluídas em resina para análise metalográfica e passaram a ser chamadas de corpo de prova. Foram analisadas macrograficamente, a olho nu, e micrograficamente, em aumento de 100X, com o uso de microscopia eletrônica.Resultados:
O resultado da análise mostrou que as quatro peças fundidas em titânio com o uso do arco voltaico apresentaram defeitos como vazios, trincas, porosidades e escórias. As quatro barras fundidas em Cobalto-Cromo, pela técnica de gás e ar, mostraram-se satisfatórias, mesmo com a presença de microestrutura dendrítica.Conclusão:
Conclui-se que a falta de qualidade, observada na fundição do Titânio, seja devida tanto a uma baixa curva de aprendizagem dos técnicos como a possíveis defeitos nos equipamentos utilizados.ABSTRACT
Objective:
To use metallographic analysis to evaluate the quality of Co-Cr and Ti CP alloy casting processes routinely used in dentures with ferrule attachment to implants.Methods:
An aluminum base simulating a mandible was machined, onto which prototype wax patterns were sculped, consisting of eight bars, measuring 3 mm in diameter with an extension of 6 cm. Four Ti bars were cast by the voltaic arch technique and four of Co-Cr alloy by the gas and air technique using a blowtorch. The eight finished bars were cut, embedded in resin for metallographic analysis, and were then called test specimens (TS). They were analyzed by the naked eye and macrographically at 100 X magnification using electronic microscopy.Results:
The analysis result showed that the four titanium castings with the use of voltaic arch presented defects such as voids, cracks, porosities and slags. The four bars cast with Co-Cr by the gas and air technique using the blowtorch were shown to be satisfactory, even with the presence of dendritic microstructure.Conclusion:
It was concluded that the lack of quality observed in these laboratory processes is due to both the low learning curve of the technicians and possible defects in the equipment used.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
BBO
/
LILACS
Assunto principal:
Titânio
/
Técnicas In Vitro
/
Ligas de Cromo
/
Técnica de Fundição Odontológica
Idioma:
Pt
Revista:
RGO (Porto Alegre)
Assunto da revista:
ODONTOLOGIA
Ano de publicação:
2009
Tipo de documento:
Article
País de afiliação:
Brasil
País de publicação:
Brasil