Desenvolvimento e validação de método analítico para nistatina creme vaginal por cromatografia líquida de alta eficiência / Development and validation of an analytical method for nystatin vaginal cream by high performance liquid chromatography
RBCF, Rev. bras. ciênc. farm. (Impr.)
; RBCF, Rev. bras. ciênc. farm. (Impr.);44(4): 637-643, out.-dez. 2008. ilus, graf, tab
Article
em Pt
| LILACS
| ID: lil-507914
Biblioteca responsável:
BR40.1
RESUMO
A nistatina é um antibiótico poliênico, com características fungistáticas e fungicidas, que age desestruturando a membrana celular de fungos e leveduras. O creme vaginal de nistatina é usado para o tratamento da candidíase vaginal. Até recentemente, os compêndios oficiais preconizavam o ensaio microbiológico para doseamento deste antibiótico, método este considerado inviável na rotina de centros de controle de qualidade, devido ao tempo excessivo para liberação dos resultados. Visando obter um método alternativo para o doseamento do creme vaginal de nistatina, procurou-se desenvolver e validar um método cromatográfico (CLAE). O método desenvolvido utilizou como fase estacionária uma coluna de fase reversa, C18, 3,9 x 150 mm, 4 mm, à temperatura de 30 ºC. A fase móvel foi constituída por tampão fosfato de sódio 0,25 mM e EDTA 0,025 mM, pH 6,00, metanol e acetonitrila (403030), vazão de 1,0 mL/minuto e comprimento de onda 305 nm. O método validado revelou-se exato, preciso, robusto, linear e específico, além de rápido e prático, podendo ser utilizado para o doseamento analítico de creme vaginal de nistatina.
ABSTRACT
Nystatin is a polyenic antibiotic with fungistatic and fungicide characteristics that acts by de-structuring the cellular membrane of fungi and yeast. The nystatin vaginal cream is used for the treatment of vaginal candidiasis. Until recently, the official compendia professed the microbiological trial for dosing this antibiotic, method considered as non-feasible in the routine of quality control centers due to the excessive time for release of results. Aiming at obtaining an alternative method for dosing nystatin vaginal cream, a chromatographic method (HPLC) was developed and validated. The method developed used a reversible phase column of C18, 3.9 x 150 mm, 4 mm, at 30 ºC. The mobile phase was made up of a 0.25 mM sodium phosphate buffer and 0.025 mM EDTA, pH 6.00, methanol and acetonitrile (403030), rate of 1.0 mL/minute and wavelength of 305 nm. The validated method showed to be accurate, precise, robust, linear and specific, in addition to being fast and practical, able to be used for analytic dosing of nystatin vaginal cream.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
LILACS
Assunto principal:
Nistatina
/
Cromatografia Líquida de Alta Pressão
/
Métodos Analíticos de Preparação de Amostras
/
Estudos de Validação como Assunto
Idioma:
Pt
Revista:
RBCF, Rev. bras. ciênc. farm. (Impr.)
Assunto da revista:
BIOQUIMICA
/
FARMACIA
/
FARMACOLOGIA
Ano de publicação:
2008
Tipo de documento:
Article
País de afiliação:
Brasil
País de publicação:
Brasil