Técnica radiográfica alternativa para o tratamento endodôntico / Alternative radiographic technique for endodontic treatment
Rev. ciênc. méd., (Campinas)
; 15(6): 507-513, nov.-dez. 2006. tab, ilus
Article
em Pt
| LILACS
| ID: lil-489192
Biblioteca responsável:
BR408.1
Localização: BR408.1
RESUMO
Objetivo O propósito deste estudo foi adaptar angulações verticais a uma técnica radiográfica extrabucal, utilizando filmes radiográficos periapicais para que possa ser empregada de forma fácil e simplificada. Métodos Onze crânios macerados com suas respectivas mandíbulas foram utilizados. Quatro fios ortodônticos de aço medindo um centímetro de comprimento foram fixados nos espaços interproximais dos dentes posteriores. Um transferidor foi empregado para estabelecer o ângulo bissetor entre dentes e filme. Uma fórmula matemática permitiu determinar as angulações verticais para cada região. As imagens radiográficas foram digitalizadas e mensuradas no software UTHSCSA Image Tool. A análise estatística empregou o teste"t" de Student. Resultados A diferença de 0,477 milímetros entre o comprimento real do fio de aço e sua respectiva imagem, encontrada neste estudo, não se apresentou clinicamente significativa. Conclusão Além da vantagem de não afetar significativamente a qualidade do diagnóstico radiográfico, a técnica extrabucal apresentou-se útil para ser empregada em grupo seletivo de pacientes.
ABSTRACT
Objective The objective of this study was to adapt vertical angles to an extraoral radiographic technique using periapical radiographic film so that it can be used in an easy and simple manner. Methods Eleven macerated skulls with their respective mandibles were used. Four 1 centimeter stainless steel wires were fixed in the interproximal spaces of the posterior teeth. A protractor was employed to establish the bisector angle between the teeth and the film. A mathematic formula allowed the determination of the vertical angulations for each region. The radiographic images were digitized and measured by specific computer software (UTHSCSA Image Tool). The statistic analysis employed the "t" Student test. Results A difference of 0.477 millimeters between the actual length of the stainless steel wire and its image was found in our study and this difference was not clinically significant. Conclusion Besides the advantage of not affecting the diagnostic quality of the radiograph significantly, the extraoral technique can also be efficiently used in a select group of patients.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
LILACS
Assunto principal:
Radiografia
/
Endodontia
Tipo de estudo:
Diagnostic_studies
Idioma:
Pt
Revista:
Rev. ciênc. méd., (Campinas)
Ano de publicação:
2006
Tipo de documento:
Article
País de afiliação:
Brasil