Your browser doesn't support javascript.
loading
Avaliação da acurácia de diversos métodos para determinação de ácidos graxos voláteis e alcalinidade a bicarbonato para monitoramento de reatores anaeróbios / Evaluation of the accuracy of several methods for determination of volatile fatty acids and bicarbonate alkalinity for the monitoring of anaerobic reactors
Ribas, Maria Magdalena Ferreira; Moraes, Elizabeth de Mattos; Foresti, Eugenio.
Afiliação
  • Ribas, Maria Magdalena Ferreira; USP. Escola de Engenharia de São Carlos. Programa de Pós-Graduação em Hidráulica e Saneamento. São Paulo. BR
  • Moraes, Elizabeth de Mattos; USP. Escola de Engenharia de São Carlos. São Carlos. BR
  • Foresti, Eugenio; USP. Escola de Engenharia de São Carlos. Departamento de Hidráulica e Saneamento. São Carlos. BR
Eng. sanit. ambient ; Eng. sanit. ambient;12(3): 240-246, jul.-set. 2007. graf, tab
Article em Pt | LILACS | ID: lil-466571
Biblioteca responsável: BR559.1
RESUMO
Sistemas de tratamento anaeróbios são sensíveis às mudanças de condições ambientais que influenciam no metabolismo dos microrganismos responsáveis pela estabilidade do processo. Os objetivos deste trabalho foram (i) avaliar a acurácia de métodos que determinam os parâmetros de controle ácidos graxos voláteis (AGV) e alcalinidade a bicarbonato (AB) em amostras preparadas com concentrações de 50 a 1000 mg/L e, (ii) verificar diferentes procedimentos de remoção de CO2 formado durante titulação ácida das amostras. A partir do teste estatístico de Tukey aplicado aos resultados obtidos, observou-se que os métodos Kapp e DiLallo & Albertson com utilização de ultra-som para a remoção de CO2 do meio líquido apresentaram os melhores resultados para AGV. Os métodos da Condutividade, Kapp e Jenkins se destacaram na determinação de AB.
ABSTRACT
Anaerobic treatment systems are sensitive to the environmental condition changes. Such changes may have influence on the metabolism of the microorganisms responsible for the process stability. The aims of this work were (i) to evaluate the accuracy of methods to determine control parameters volatile fatty acids (VFA) and bicarbonate alkalinity (BA) in samples prepared with concentrations from 50 to 1000 mg/L and, (ii) to verify different procedures of the CO2 removal formed during the acid titration of the samples. From the Tukey statistical test applied to the obtained results it was observed that the Kapp and DiLallo & Albertson methods using sonic equipment to remove CO2 from the liquid presented better results for VFA. The Conductivity, Kapp and Jenkins methods were considered the most reliable for BA determination.
Assuntos
Palavras-chave
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Condutividade Térmica / Bicarbonatos / Digestão Anaeróbia / Monitoramento Ambiental / Reatores Anaeróbios de Fluxo Ascendente / Ácidos Graxos Voláteis Idioma: Pt Revista: Eng. sanit. ambient Assunto da revista: SAUDE AMBIENTAL / SAUDE PUBLICA Ano de publicação: 2007 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Condutividade Térmica / Bicarbonatos / Digestão Anaeróbia / Monitoramento Ambiental / Reatores Anaeróbios de Fluxo Ascendente / Ácidos Graxos Voláteis Idioma: Pt Revista: Eng. sanit. ambient Assunto da revista: SAUDE AMBIENTAL / SAUDE PUBLICA Ano de publicação: 2007 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil