Condromalácia de patela: comparação entre os achados em aparelhos de RM de alto e baixo campo magnético / Chondromalacia patellae: comparison of high-field strength versus low-field strength magnetic resonance imaging findings
Radiol. bras
; Radiol. bras;39(3): 167-174, maio-jun. 2006. tab, ilus
Article
em Pt
| LILACS
| ID: lil-455877
Biblioteca responsável:
BR734.1
RESUMO
OBJETIVO:
Comparar os aparelhos de ressonância magnética de baixo campo e de alto campo para estudo da cartilagem articular da patela.MATERIAIS E MÉTODOS:
Foi realizado estudo usando as seqüências GRE 2D, GRE 3D, FSE T2 e STIR (baixo campo) e TSE T2 SPIR. Cada seqüência foi analisada separadamente para o estudo da cartilagem, sem o conhecimento dos dados do paciente e do resultado das outras seqüências, sendo atribuído grau de lesão de 0 a 3 e descrita a sua localização. Os resultados de concordância e discordância foram analisados pelos testes de Kappa e McNemar.RESULTADOS:
Na faceta medial houve baixas concordâncias e as discordâncias mostraram significativa superestimação. Na faceta lateral houve boas concordâncias e as discordâncias não foram significativas. No ápice houve boas concordâncias e as discordâncias mostraram significativa subestimação.CONCLUSÃO:
A seqüência STIR teve a melhor concordância com a seqüência TSE T2 SPIR. Lesões de alto grau são mais bem caracterizadas pelas seqüências do aparelho de baixo campo. Areas de aumento de sinal dificultam o estudo da cartilagem da faceta medial da patela no aparelho de baixo campo.ABSTRACT
OBJECTIVE:
To compare the performance of low-field-strength and high-field-strength magnetic resonance imaging equipments for evaluation of the patella articular cartilage. MATERIALS ANDMETHODS:
The study was developed using GRE 2D, GRE 3D, FSE T2, STIR sequences (low-field) and TSE T2 SPIR sequence. Each sequence has been separately analyzed for evaluation of the cartilage without knowledge of other sequences results or any patients data; the lesion was assigned a grade from 0 to 3 and had its location defined. Agreement and disagreement results were analyzed by Kappa and McNemar tests.RESULTS:
Medial facet has presented low agreement index and disagreements showed to be significantly overestimated. Lateral facet has presented a reasonable agreement index and disagreement index was not significant. Medial ridge has presented a reasonable agreement index and disagreement index has showed to be underestimated.CONCLUSION:
The STIR sequence versus TSE T2 SPIR sequence has presented the higher agreement index. High grade lesions are better characterized by low-field-strength magnetic resonance imaging equipment sequences. Areas of increased signal intensity make difficult the study of the patella medial facet cartilage in low-field-strength equipment.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
LILACS
Assunto principal:
Imageamento por Ressonância Magnética
/
Condromalacia da Patela
/
Equipamentos e Provisões
Tipo de estudo:
Diagnostic_studies
Limite:
Adolescent
/
Adult
/
Female
/
Humans
/
Male
Idioma:
Pt
Revista:
Radiol. bras
Assunto da revista:
DIAGNOSTICO POR IMAGEM
/
RADIOLOGIA
Ano de publicação:
2006
Tipo de documento:
Article
País de afiliação:
Brasil
País de publicação:
Brasil