Your browser doesn't support javascript.
loading
Método para a correção da distorção de imagens obtidas por videofluoroscopia / Method for correction of distortions in images acquired by videofluoroscopy
Silveira, Luis Felipe; Loss, Jefferson Fagundes; Cañeiro, João Paulo; Bernardes, Caroline; Aldabe, Daniela; Araujo, Manoel Angelo de.
Afiliação
  • Silveira, Luis Felipe; UFRGS. Escola de Educação Física. Lapex. Porto Alegre. BR
  • Loss, Jefferson Fagundes; UFRGS. Escola de Educação Física. Lapex. Porto Alegre. BR
  • Cañeiro, João Paulo; UFRGS. Escola de Educação Física. Lapex. Porto Alegre. BR
  • Bernardes, Caroline; UFRGS. Escola de Educação Física. Lapex. Porto Alegre. BR
  • Aldabe, Daniela; UFRGS. Escola de Educação Física. Lapex. Porto Alegre. BR
  • Araujo, Manoel Angelo de; Hospital da Criança Conceição. Serviço de Radiologia Pediátrica. Porto Alegre. BR
Radiol. bras ; Radiol. bras;38(6): 427-430, nov.-dez. 2005. ilus, graf
Article em Pt | LILACS | ID: lil-421246
Biblioteca responsável: BR734.1
RESUMO

OBJETIVO:

Operacionalizar um protocolo para a correção de imagens obtidas por videofluoroscopia a partir de um modelo matemático descrito por Baltzopoulos (1995) e avaliar a magnitude do erro pelos métodos de calibração linear e não linear.

MATERIAIS E MÉTODOS:

As imagens foram obtidas por meio de um videofluoroscópio da marca Axion Siemens Iconos R100 de um indivíduo realizando exercício de extensão de joelho. Para a correção das imagens foi utilizado padrão de calibração não-linear. O processamento dos dados foi realizado em placa de captura da marca Silicon Graphics 320 e posteriormente analisado em um "software" Matlab.

RESULTADOS:

Para demonstrar a aplicabilidade do método foi avaliada a deformação do ligamento patelar. A utilização do padrão de calibração linear produziu um erro máximo de 0,086 mm, enquanto o padrão de calibração não linear atingiu um valor máximo de 0,019 mm. Já com relação ao erro médio, a calibração linear atingiu o valor de 0,024 mm, e a não linear apresentou um valor de 0,007 mm.

CONCLUSÃO:

Os resultados evidenciam a necessidade de utilização de um procedimento de calibração não linear.
ABSTRACT

OBJECTIVE:

To implement a protocol for correction of images acquired by videofluoroscopy based on the mathematical model described by Baltzopoulos (1995) and to evaluate the magnitude of error in the linear and non-linear calibration methods. MATERIALS AND

METHODS:

The images were acquired using a Axion Siemens Iconos R100 videofluoroscope from one individual during knee extension exercise. A non-linear calibration pattern was used for the correction of the images. Data was processed using a Silicon Graphics 320 capture plate and subsequently analyzed using the Matlab software.

RESULTS:

In order to demonstrate the method's applicability, the deformation of the patellar ligament was evaluated. The use of a linear calibration pattern produced a maximum error of 0.086 mm, while the non-linear calibration pattern reached a maximum value of 0.019 mm. According to the mean error, the linear calibration was 0.024 mm, and the non-linear presented a value of 0.007 mm.

CONCLUSION:

The results show the need to use a non-linear calibration procedure.
Assuntos
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Processamento de Imagem Assistida por Computador / Diagnóstico por Imagem / Fluoroscopia / Ligamento Patelar Tipo de estudo: Diagnostic_studies / Guideline Limite: Adult Idioma: Pt Revista: Radiol. bras Assunto da revista: DIAGNOSTICO POR IMAGEM / RADIOLOGIA Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Processamento de Imagem Assistida por Computador / Diagnóstico por Imagem / Fluoroscopia / Ligamento Patelar Tipo de estudo: Diagnostic_studies / Guideline Limite: Adult Idioma: Pt Revista: Radiol. bras Assunto da revista: DIAGNOSTICO POR IMAGEM / RADIOLOGIA Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil